INTRODUCTION
This research is a pilot, single-blinded study investigating heart rate variability (HRV) during auricular acupressure at the left sympathetic point (AH7) in healthy volunteers.
METHODS
There were 120 healthy volunteers with hemodynamic indexes (heart rate, blood pressure) within normal ranges, randomly divided into two groups AG and SG (in each group having a gender ratio 1:1, aged 20-29), to receive either auricular acupressure using ear seed (AG) or sham method using adhesive patches without seed (SG) at the left sympathetic point while lying in a supine position. Acupressure intervention lasted 25 min, and HRV was recorded by a photoplethysmography device-namely, Kyto HRM-2511B and Elite appliance.
RESULTS
Auricular acupressure at the left Sympathetic point (AG) led to a significant reduction in heart rate (HR) ( < 0.05) and a considerable increase in HRV parameters demonstrated by HF (High-frequency power) ( < 0.05), compared to sham auricular acupressure (SG). However, no significant changes in LF (Low-frequency power) and RR (Respiratory rate) ( > 0.05) were observed in both groups during the process.
CONCLUSION
These findings suggest that auricular acupressure at the left sympathetic point may activate the parasympathetic nervous system while a healthy person is lying relaxed.
引言
本研究是一项试点单盲研究,旨在调查健康志愿者在左耳交感点(AH7)进行耳穴按压时的心率变异性(HRV)。
方法
120名血液动力学指标(心率、血压)在正常范围内的健康志愿者,随机分为AG组和SG组(每组性别比为1:1,年龄20 - 29岁),仰卧位时在左耳交感点分别接受耳穴压籽法(AG组)或无籽贴片假刺激法(SG组)。按压干预持续25分钟,通过光电容积描记术设备(即Kyto HRM - 2511B和Elite仪器)记录HRV。
结果
与假耳穴按压(SG组)相比,左耳交感点耳穴按压(AG组)导致心率(HR)显著降低(<0.05),高频功率(HF)显示的HRV参数显著增加(<0.05)。然而,在此过程中两组的低频功率(LF)和呼吸频率(RR)均未观察到显著变化(>0.05)。
结论
这些发现表明,在健康人放松仰卧时,左耳交感点耳穴按压可能会激活副交感神经系统。