Suppr超能文献

进行性言语失用症中多巴胺转运体摄取扫描的纵向变化。

Longitudinal changes in dopamine transporter uptake scans in progressive apraxia of speech.

作者信息

Utianski Rene L, Trang Thu Pham Nha, Botha Hugo, Ali Farwa, Duffy Joseph R, Clark Heather M, Lowe Val J, Whitwell Jennifer L, Josephs Keith A

机构信息

Departments of Neurology, and, Mayo Clinic, Rochester, MN, USA.

Health Sciences Research, and, Mayo Clinic, Rochester, MN, USA.

出版信息

Clin Park Relat Disord. 2023 Jun 16;9:100207. doi: 10.1016/j.prdoa.2023.100207. eCollection 2023.

Abstract

PURPOSE

To describe qualitative and quantitative longitudinal changes in dopamine transporter uptake (DaT) scan findings in progressive apraxia of speech (PAOS) patients.

METHODS

DaTQUANT software was used to quantify uptake in the left and right caudate and putamen in DaT scans of 39 patients with PAOS, 19 with repeat scans. Clinical radiologic impressions were used as the gold standard for evaluating whether quantitative measures (z-score of left and right putamen and caudate uptake) aligned with gestalt impressions of DaT abnormalities and clinical impairments, cross-sectionally. Measures at first and last available DaT were used to evaluate change over time and the influence of qualitative abnormality at first visit on change over time.

RESULTS

Cross-sectionally, 16/39 patients had abnormal DaT scans on visual read, with differences in all quantitative DaT measures between those with (ab)normal scans, but without differences in any clinical measures (apraxia of speech, aphasia, or parkinsonism). Three patients that had normal DaT scans at baseline were read as abnormal at subsequent visits, with coinciding change in quantitative measures. At the group level, across the 19 patients with repeat imaging, no statistical change in left or right caudate or putamen scores was observed despite progression of clinical indices. Abnormality at first visit did not statistically influence the rate of change over time, although trends were observed.

CONCLUSIONS

Approximately 40-50% of patients with PAOS have or will develop DaT scans that may be visually read as abnormal. Quantitative measures of DaT match visual reads cross-sectionally, but may not map to clinical progression, including of parkinsonism, observed in these patients.

摘要

目的

描述进行性言语失用症(PAOS)患者多巴胺转运体摄取(DaT)扫描结果的定性和定量纵向变化。

方法

使用DaTQUANT软件对39例PAOS患者的DaT扫描中左、右尾状核和壳核的摄取进行定量分析,其中19例患者进行了重复扫描。临床影像学印象被用作评估定量指标(左、右壳核和尾状核摄取的z分数)与DaT异常和临床损伤的整体印象在横断面是否一致的金标准。首次和最后一次可获得的DaT测量值用于评估随时间的变化以及首次就诊时定性异常对随时间变化的影响。

结果

横断面分析中,16/39例患者的DaT扫描视觉读片异常,扫描正常和异常患者的所有DaT定量指标存在差异,但任何临床指标(言语失用症、失语症或帕金森症)均无差异。3例基线DaT扫描正常的患者在后续就诊时读片为异常,定量指标也有相应变化。在组水平上,对19例进行重复成像的患者而言,尽管临床指标有所进展,但左、右尾状核或壳核分数未观察到统计学变化。首次就诊时的异常在统计学上并未影响随时间的变化率,尽管观察到了一些趋势。

结论

约40%-50%的PAOS患者已出现或将会出现DaT扫描视觉读片异常。DaT的定量指标在横断面与视觉读片结果相符,但可能与这些患者观察到的临床进展不相关,包括帕金森症的进展。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0623/10282401/782e91ee0850/gr1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验