热敏感度的空间总和仅限于小区域:前额、前臂、腹部和足部的比较。

Spatial summation of thermal sensitivity is limited to small areas: Comparisons of the forehead, forearm, abdomen, and foot.

机构信息

Department of Textiles, Merchandising and Fashion Design, Seoul National University, Seoul, South Korea.

Department of Textiles, Merchandising and Fashion Design, Seoul National University, Seoul, South Korea; Research Institute for Human Ecology, Seoul National University, Seoul, South Korea; Graphene Research Center for Convergence Technology, Advanced Institute of Convergence Technology, Suwon, South Korea.

出版信息

J Therm Biol. 2023 Jul;115:103627. doi: 10.1016/j.jtherbio.2023.103627. Epub 2023 Jun 17.

Abstract

The purpose of the present study was to examine if spatial summation in thermal sensitivity exists when stimulating areas larger than about 1% of body surface area (BSA) (approximately 200 cm). We hypothesized that spatial summation would exist within a limited area and the effect would be insignificant for over the 1%BSA. Fifteen young males participated in this study and we measured their warmth and hot sensation thresholds on the four body regions (the forehead, forearm, abdomen, and instep) using the three sizes of radiant film heaters (10 × 10, 15 × 15, and 20 × 20 cm heating film area). The heating panel was kept at a distance of 10 cm from the skin and the surface temperature of the heating panel increased by 1 °C·s. The results showed that warmth and hot sensation thresholds were higher for the 100 cm condition than the 225 or 400 cm conditions (P < 0.05), but no differences were found between the 225 and 400 cm conditions. Secondly, the instep was most insensitive to the gradual increase of radiant heat among the four body regions for all three stimulating film sizes, even though the hot threshold was lowest for the instep because the initial foot temperature was lower than other skin temperatures. In summary, spatial summation in thermal sensitivity was found for the 100 and 225 cm conditions, but not for the 225 and 400 cm conditions. These results suggest that spatial summation exists but limited to small stimulating areas, smaller than approximately 1% BSA.

摘要

本研究旨在考察当刺激面积大于约 1%体表面积(BSA)(约 200 cm)时,热感觉是否存在空间总和。我们假设在有限的区域内会存在空间总和,并且对于超过 1%BSA 的区域,这种效应将不显著。15 名年轻男性参与了这项研究,我们使用三种大小的辐射膜加热器(10×10、15×15 和 20×20 cm 加热膜面积)测量了他们在四个身体部位(额头、前臂、腹部和脚背)的温暖和热感觉阈值。加热板与皮肤保持 10 cm 的距离,加热板的表面温度以 1°C·s 的速度升高。结果表明,与 225 或 400 cm 条件相比,100 cm 条件下的温暖和热感觉阈值较高(P<0.05),但 225 和 400 cm 条件之间没有差异。其次,在所有三种刺激膜尺寸中,脚背对于辐射热的逐渐增加最不敏感,尽管脚背的热阈值最低,因为初始足部温度低于其他皮肤温度。总之,在 100 和 225 cm 条件下发现了热感觉的空间总和,但在 225 和 400 cm 条件下没有发现。这些结果表明,空间总和存在,但仅限于较小的刺激区域,小于大约 1%BSA。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验