Suppr超能文献

IVIM 参数与微血管结构的相关性:横纹肌肉瘤原位模型 MRI 图像与病理切片的直接比较。

Correlation between IVIM parameters and microvessel architecture: direct comparison of MRI images and pathological slices in an orthotopic murine model of rhabdomyosarcoma.

机构信息

Department of Pathology, The Second Hospital, Dalian Medical University, 467 Zhongshan Road, Dalian, China.

Department of Radiology, The Second Hospital, Dalian Medical University, 467 Zhongshan Road, Dalian, 116027, China.

出版信息

Eur Radiol. 2023 Dec;33(12):8576-8584. doi: 10.1007/s00330-023-09835-2. Epub 2023 Jun 27.

Abstract

OBJECTIVE

This study aimed to explore the correlation between intravoxel incoherent motion (IVIM) parameters and microvessel architecture (microvessel density (MVD), vasculogenic mimicry (VM), and pericyte coverage index (PCI)) in an orthotopic murine model of rhabdomyosarcoma.

METHODS

The murine model was established by injecting rhabdomyosarcoma-derived (RD) cells into the muscle. Nude mice underwent routine magnetic resonance imaging (MRI) and IVIM examinations with ten b values (0, 50, 100, 150, 200, 400, 600, 800, 1000, and 2000 s/mm). D, D*, and f values were calculated with the ADW4.7 workstation. MRI images and pathological slices were directly compared to ensure that radiology parameters accurately reflect pathology. MVD, VM, PCI, and cellularity were obtained by histological analysis. The correlations were assessed between IVIM parameters (D, D*, f, and fD* values) and pathological markers (MVD, VM, PCI, and cellularity).

RESULTS

The average of D, D*, f, and fD* values were 0.55 ± 0.07 × 10mm/s, 5.25 ± 0.73 × 10mm/s, 13.39 ± 7.68%, and 0.73 ± 0.49 × 10mm/s, respectively. The average of MVD, VM, PCI, and cellularity were 41.91 ± 10.98, 1.16 ± 0.83, 0.49 ± 0.18, and 39.15 ± 9.00%. D*, f, and fD* values showed a positive correlation with MVD separately, while the D value did not correlate with MVD. D value negatively correlated to VM moderately, and other parameters did not associate with VM. D* and fD* values were positively correlated with PCI, but no correlation was observed between other parameters and PCI.

CONCLUSIONS

IVIM may evaluate the tumor microvessel architecture. D*, f, and fD* may reflect the endothelial lining blood vessel; D could indirectly reflect the VM; D* and fD* could reflect PCI(the normal degree of the tumor blood vessel).

CLINICAL RELEVANCE STATEMENT

An intravoxel incoherent motion may be useful in assessing rhabdomyosarcoma microvessel structure to predict the target and effectiveness of anti-angiogenic therapy.

KEY POINTS

• IVIM may be used to evaluate the tumor microvessel architecture in the mouse rhabdomyosarcoma model. • The MRI-pathology control method achieves correspondence between MRI slices and pathology slices, which ensures the consistency of the ROI of MRI and the pathology observation region.

摘要

目的

本研究旨在探讨体素内不相干运动(IVIM)参数与横纹肌肉瘤原位模型中小血管结构(微血管密度(MVD)、血管生成拟态(VM)和周细胞覆盖率指数(PCI))之间的相关性。

方法

通过将横纹肌肉瘤衍生(RD)细胞注入肌肉来建立鼠模型。裸鼠接受常规磁共振成像(MRI)和 IVIM 检查,共十个 b 值(0、50、100、150、200、400、600、800、1000 和 2000 s/mm)。使用 ADW4.7 工作站计算 D、D和 f 值。直接比较 MRI 图像和病理切片,以确保放射学参数准确反映病理学。通过组织学分析获得 MVD、VM、PCI 和细胞密度。评估 IVIM 参数(D、D、f 和 fD*值)与病理标志物(MVD、VM、PCI 和细胞密度)之间的相关性。

结果

D、D*、f 和 fD值的平均值分别为 0.55±0.07×10mm/s、5.25±0.73×10mm/s、13.39±7.68%和 0.73±0.49×10mm/s。MVD、VM、PCI 和细胞密度的平均值分别为 41.91±10.98、1.16±0.83、0.49±0.18 和 39.15±9.00%。D、f 和 fD值与 MVD 呈正相关,而 D 值与 MVD 无相关性。D 值与 VM 呈中度负相关,而其他参数与 VM 无相关性。D和 fD*值与 PCI 呈正相关,但其他参数与 PCI 无相关性。

结论

IVIM 可用于评估肿瘤微血管结构。D*、f 和 fD可反映内皮衬里血管;D 可间接反映 VM;D和 fD*可反映 PCI(肿瘤血管的正常程度)。

临床相关性声明

体素内不相干运动可能有助于评估横纹肌肉瘤微血管结构,以预测抗血管生成治疗的靶标和效果。

要点

• IVIM 可用于评估小鼠横纹肌肉瘤模型中的肿瘤微血管结构。• MRI-病理学对照方法实现了 MRI 切片与病理切片的对应,确保了 MRI 感兴趣区与病理学观察区的一致性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验