Suppr超能文献

金属过敏患者行低致敏性全膝关节置换术后的情况更糟吗?对医疗保健利用和患者报告的结果测量指标的分析。

Do Patients With Hypoallergenic Total Knee Arthroplasty Implants for Metal Allergy Do Worse? An Analysis of Health Care Utilizations and Patient-Reported Outcome Measures.

机构信息

Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio; College of Medicine, Northeast Ohio Medical University, Rootstown, Ohio.

Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio.

出版信息

J Arthroplasty. 2024 Jan;39(1):103-110. doi: 10.1016/j.arth.2023.07.005. Epub 2023 Jul 15.

Abstract

BACKGROUND

Metal allergy is a rare and controversial cause of implant failure and poor outcomes following total knee arthroplasty (TKA). Few studies have investigated clinical and patient-reported outcome measures (PROMs) in patients treated with hypoallergenic implants. This investigation aimed to compare: (1) health care utilizations (eg, hospital length of stay, 90-day readmission rate, and incidence of nonhome discharge) and (2) 1-year PROMs between patients who received hypoallergenic and standard TKA implants.

METHODS

This was a retrospective review of prospectively collected data from patients who underwent primary TKA between 2018 and 2019. Propensity score matching (3:1) was used to compare standard TKA patients with those who received hypoallergenic TKA implants, respectively. Knee injury and Osteoarthritis Outcome Score (KOOS) pain, KOOS Physical function Shortform (PS), and Veterans RAND 12-Item Health Survey Mental Component Score were collected preoperatively and at 1-year. After matching, 190 hypoallergenic and 570 standard TKAs were analyzed.

RESULTS

No differences were observed in length of stay (P = .98), 90-day readmission (P = .89), and nonhome discharge (P = .82). Additionally, there was no significant difference in change from preoperative to 1-year PROMs (KOOS pain, P = .97; KOOS PS, P = .88; Veterans RAND 12-Item Health Survey Mental Component Score, P = .28). Patient-reported satisfaction was similar at 1-year (P = .23). Patients achieved similar rates of Patient Acceptable Symptom State (PASS) and minimal clinically important difference (MCID) for KOOS pain (PASS, P = .77; MCID, P = .33) and KOOS PS (PASS, P = .44; MCID, P = .65).

CONCLUSION

Patients treated with hypoallergenic TKA implants for suspected metal allergy had similar outcomes compared to patients who had standard implants and no metal allergy.

摘要

背景

金属过敏是全膝关节置换术(TKA)后假体失败和预后不良的罕见且有争议的原因。很少有研究调查过接受低致敏性植入物治疗的患者的临床和患者报告的结果测量(PROMs)。本研究旨在比较:(1)医疗保健利用率(例如,住院时间、90 天再入院率和非家庭出院率)和(2)接受低致敏性和标准 TKA 植入物治疗的患者的 1 年 PROMs。

方法

这是对 2018 年至 2019 年间接受初次 TKA 的患者前瞻性收集数据的回顾性研究。使用倾向评分匹配(3:1)分别比较标准 TKA 患者和接受低致敏性 TKA 植入物的患者。在术前和 1 年时收集膝关节损伤和骨关节炎结果评分(KOOS)疼痛、KOOS 身体功能简表(PS)和退伍军人 RAND 12 项健康调查心理成分评分。匹配后,分析了 190 例低致敏性和 570 例标准 TKA。

结果

住院时间(P=0.98)、90 天再入院率(P=0.89)和非家庭出院率(P=0.82)无差异。此外,从术前到 1 年的 PROM 变化也没有显著差异(KOOS 疼痛,P=0.97;KOOS PS,P=0.88;退伍军人 RAND 12 项健康调查心理成分评分,P=0.28)。1 年时患者报告的满意度相似(P=0.23)。接受低致敏性 TKA 植入物治疗疑似金属过敏的患者与接受标准植入物且无金属过敏的患者获得相似的患者可接受症状状态(PASS)和最小临床重要差异(MCID)率 KOOS 疼痛(PASS,P=0.77;MCID,P=0.33)和 KOOS PS(PASS,P=0.44;MCID,P=0.65)。

结论

与接受标准植入物且无金属过敏的患者相比,接受低致敏性 TKA 植入物治疗的疑似金属过敏患者的结果相似。