Abouharb Alexander, Joseph Prince Josiah Sajanthan, Pandit Hemant
University of Leeds, Leeds, West Yorkshire, UK.
University of Liverpool, Liverpool, Merseyside, UK.
Arthroplast Today. 2024 Jul 27;28:101462. doi: 10.1016/j.artd.2024.101462. eCollection 2024 Aug.
Metal sensitivity is a possible cause for revision in elective lower-limb arthroplasty. This scoping review aims to identify and evaluate all existing and novel assessment methods for metal sensitivity in elective lower-limb arthroplasty.
The Cochrane Central Register of Controlled Trials (CENTRAL), Ovid Medical Literature Analysis and Retrieval System Online (MEDLINE), PubMed, and Google Scholar databases were searched for studies published between January 1, 2000, and September 1, 2023. Studies evaluating one or more metal sensitivity assessment method preoperatively, perioperatively, or postoperatively were included. Studies were grouped based on the assessment methods reported and summarized based on the study design, outcome measure, results, and comments on the method's validity.
A total of 1220 results were screened, with 39 results (15 retrospective cohort studies, 11 prospective cohort studies, 6 case reports, 5 randomized controlled trials, and 2 case control studies) included, identifying 12 assessment methods. The most used one was patch testing, featuring in 17 studies (43.6%). Lymphocyte transformation assay/testing featured in 12 studies (30.8%). Plasma/serum concentration of metal ions featured in 6 studies (15.4%). Patient history and serum cytokine testing featured in 7 (17.9%) and 4 (10.3%) studies each. Generalized serum inflammatory markers featured in 3 studies (7.7%). The remaining 6 methods each featured in one or 2 studies. Evidence of the reliability of most metrics was limited.
Several assessment methods were identified. However, evidence of any methods reliably predicting and diagnosing the occurrence of metal sensitivity was limited. There is a need for improved metrics of metal hypersensitivity.
金属敏感性是择期下肢关节置换术翻修的一个可能原因。本范围综述旨在识别和评估择期下肢关节置换术中金属敏感性的所有现有和新型评估方法。
检索Cochrane对照试验中心注册库(CENTRAL)、Ovid医学文献分析与检索系统在线版(MEDLINE)、PubMed和谷歌学术数据库,查找2000年1月1日至2023年9月1日期间发表的研究。纳入术前、术中或术后评估一种或多种金属敏感性评估方法的研究。根据报告的评估方法对研究进行分组,并根据研究设计、结局指标、结果以及对方法有效性的评论进行总结。
共筛选出1220项结果,纳入39项结果(15项回顾性队列研究、11项前瞻性队列研究、6项病例报告、5项随机对照试验和2项病例对照研究),确定了12种评估方法。使用最多的是斑贴试验,17项研究(43.6%)中有该方法。淋巴细胞转化试验/检测在12项研究(30.8%)中有出现。金属离子的血浆/血清浓度在6项研究(15.4%)中有出现。患者病史和血清细胞因子检测分别在7项(17.9%)和4项(10.3%)研究中有出现。全身性血清炎症标志物在3项研究(7.7%)中有出现。其余6种方法每项在1项或2项研究中有出现。大多数指标可靠性的证据有限。
确定了几种评估方法。然而,任何方法可靠预测和诊断金属敏感性发生的证据有限。需要改进金属超敏反应的指标。