A commercial low-profile cross-ventilated system (LPCV) free-stall barn with evaporative cooling pads on the air intake side was used to assess the potential of cross-ventilation with evaporative cooling to alleviate heat stress in lactating dairy cows. A total of 5712 records (238 days × 24 h) of air temperature (AT) and relative humidity (RH) values were collected. In order to state the effectiveness of the ventilation system and potential heat stress, the temperature humidity index (THI) and enthalpy (h) were calculated outside and inside the LPCV barn. The cooling capacity of the LPCV system is greater in conditions of low humidity, and the difference between the values of the internal and external temperature reached -12 °C. The LPCV reduced exposure to heat stress, increasing the time cows spent in thermoneutral conditions. This system could reduce the occurrence of temperature above 25 °C from 33 to 5% and 11% in sections A (represents the inlet side of the barn) and D (represents the outlet side of the barn), respectively. On the other hand, the LPCV kept a high and constant rate of RH throughout the day. The average inside and outside AT were significantly different, but differences in temperature were observed across the width of the barn. Analyzing the barn by the indexes, the THI showed that the barn promoted cows more time confined under non-stressful thermal conditions (between 83.8 and 90% vs 68.7%) and stress period much lower compared to the external environment (between 10 and 16.2% vs. 31.3%). The enthalpy index showed that there was not much difference between the internal and external environments. The LPCV system is another installation alternative for raising dairy cow in a hot and humid climate.

摘要

采用商业低轮廓交叉通风(LPCV)自由站立牛舍,在进风侧安装蒸发冷却垫,评估交叉通风与蒸发冷却相结合缓解泌乳奶牛热应激的潜力。共收集了 5712 条空气温度(AT)和相对湿度(RH)记录(238 天×24 小时)。为了说明通风系统的有效性和潜在的热应激,计算了 LPCV 牛舍内外的温度湿度指数(THI)和焓(h)。在低湿度条件下,LPCV 系统的冷却能力更大,内部和外部温度值的差异达到-12°C。LPCV 减少了热应激的暴露,增加了奶牛处于热中性条件下的时间。该系统可将 A 区(代表牛舍入口侧)和 D 区(代表牛舍出口侧)的温度超过 25°C 的发生频率从 33%和 11%分别降低到 5%和 1%。另一方面,LPCV 全天保持高且恒定的 RH 率。内部和外部 AT 的平均值差异显著,但在牛舍宽度上存在温度差异。通过指标分析牛舍,THI 表明,与外部环境相比,牛舍使奶牛在非应激热条件下(83.8%至 90%与 68.7%)和应激期的时间更长(10%至 16.2%与 31.3%)。焓指数表明,内部和外部环境之间没有太大差异。LPCV 系统是在炎热潮湿气候下饲养奶牛的另一种安装选择。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验