Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, 300070, China.
Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, 300020, China.
Int Ophthalmol. 2023 Nov;43(11):4111-4120. doi: 10.1007/s10792-023-02812-0. Epub 2023 Jul 22.
Dysfunctional lens index (DLI) changing is rarely reported after implantable collamer lens (ICL) implantation. In the current research, we hope to investigate the changes of DLI by ray-tracing aberrometry before and after implantation of the posterior chamber phakic implantable collamer lens with a central artificial hole for patients with moderate-to-high myopia.
This retrospective, observational case series included 206 eyes of 104 patients with moderate-to-high myopia who underwent ICL V4c implantation. Data were collected on ocular indicators preoperatively and at 1 day, 1, 3, and 6 months postoperatively. The i-Trace Visual Functional Analyzer was used to assess the DLI measurement.
The overall values of safety index and efficacy index were both more than 1. Preoperatively, the mean spherical equivalent (SE) of included 206 eyes was - 10.77 ± 3.46 diopter (D). Then at 1-day postoperation, the mean SE was - 0.22 ± 0.55 D, and barely changed from 1 day to 6 months postoperatively. Although the endothelial parameters had no significant differences between preoperation and postoperation, the mean loss of endothelial cells was 0.74 ± 0.98% at 6 months. Regarding the vault, there was a significant difference between each time of follow-up (P < 0.001). The mean of the vault decreased 109.6 ± 13.5 µm from 1-day post-op to 6 months post-op. The DLI values were 3.70, 9.26, 10.00, and 9.68 at baseline, 1, 3, and 6 months, respectively (P < 0.001), but no significant differences were found between 1, 3, and 6 months postoperatively (P > 0.05). The preoperative lnDLI showed a significant positive linear correlation (r = 0.621, P < 0.001) with the preoperative spherical equivalent (SE). The lnDLI was negatively correlated with the axial length (r = - 0.462, P < 0.001), corneal thickness (r = - 0.207, P = 0.003), preoperative LogMAR UDVA (r = - 0.189, P = 0.006), and preoperative LogMAR CDVA (r = - 0.306, P < 0.001).
The postoperative refractive parameters were confirmed excellent in efficacy, predictability, and stability in half a year. The DLI was significantly improved after the ICL V4c implantation in patients with moderate-to-high myopia and showed good stability during the follow-up periods. The DLI deserves a more comprehensive understanding and application in clinical services.
人工晶状体植入术后屈光度指数(DLI)改变很少见。在当前的研究中,我们希望通过对具有中央人工孔的后房有晶状体眼可植入Collamer 透镜(ICL)植入术后的患者的眼前节像差仪来研究 DLI 的变化,这些患者为中高度近视。
本回顾性观察性病例系列研究纳入了 104 例 206 只眼的中高度近视患者,这些患者均接受了 ICL V4c 植入术。在术前和术后 1 天、1 个月、3 个月和 6 个月收集眼部指标。使用 i-Trace 视觉功能分析仪评估 DLI 测量值。
安全性指数和有效性指数的总体值均大于 1。术前,206 只眼中的平均等效球镜(SE)为-10.77±3.46 屈光度(D)。然后,术后 1 天 SE 为-0.22±0.55 D,术后 1 天至 6 个月几乎没有变化。尽管内皮细胞参数在术前和术后无显著差异,但术后 6 个月内皮细胞丢失率为 0.74±0.98%。关于拱高,每次随访均有显著差异(P<0.001)。术后 1 天至 6 个月,拱高平均下降 109.6±13.5 µm。DLI 值分别为基线时 3.70、术后 1 天 9.26、术后 3 天 10.00 和术后 6 天 9.68(P<0.001),但术后 1、3 和 6 个月之间无显著差异(P>0.05)。术前 lnDLI 与术前等效球镜(SE)呈显著正线性相关(r=0.621,P<0.001)。lnDLI 与眼轴长度(r=-0.462,P<0.001)、角膜厚度(r=-0.207,P=0.003)、术前 LogMAR 远视力(r=-0.189,P=0.006)和术前 LogMAR 中心视力(r=-0.306,P<0.001)呈负相关。
术后半年,屈光参数在疗效、可预测性和稳定性方面均表现出色。中高度近视患者 ICL V4c 植入术后 DLI 显著改善,随访期间稳定性良好。DLI 值得在临床服务中进行更全面的理解和应用。