Faria-Correia Fernando, Ramos Isaac, Lopes Bernardo, Monteiro Tiago, Franqueira Nuno, Ambrósio Renato
J Refract Surg. 2017 Feb 1;33(2):79-83. doi: 10.3928/1081597X-20161206-05.
To study the relationship between objective metrics for quantifying crystalline lens dysfunction with visual impairment and phacodynamics parameters in age-related nuclear cataracts.
A total of 51 eyes (34 patients) with age-related nuclear cataract had phacoemulsification. The Dysfunctional Lens Index (0 to 10 points) was measured by a ray-tracing aberrometry (iTrace Visual Function Analyzer; Tracey Technologies, Houston, TX). The average lens density (0 to 100) was evaluated using a rotating Scheimpflug system (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany), and the nuclear opalescence score was subjectively assessed using the Lens Opacities Classification System III (LOCS III). The different parameters for evaluating crystalline lens dysfunction were correlated with preoperative corrected distance visual acuity (CDVA) and cumulative dissipated energy (CDE).
There was a negative linear correlation between the Dysfunctional Lens Index and the LOCS III nuclear opalescence and Scheimpflug-measured average density (r =-0.728 and r = -0.771, respectively; both P < .01). The preoperative CDVA was correlated with the Scheimpflug-measured lens nuclear density value (r = 0.612, P < .01) and Dysfunctional Lens Index score A (r =-0.670, P < .01). The CDE was more strongly correlated with Dysfunctional Lens Index and Scheimpflug-derived average density (r =-0.744 and r = 0.700, respectively; both P < .01) than with LOCS III nuclear opalescence (r = 0.646, P < .01).
The Dysfunctional Lens Index was correlated with the Scheimpflug-measured average density, subjective lens grading, and preoperative CDVA. This metric also presented the highest correlation with phacodynamics. Correlation with other clinical measures related to visual quality and impairment are still needed. [J Cataract Refract Surg. 2017;33(2):79-83.].
研究年龄相关性核性白内障中,量化晶状体功能障碍的客观指标与视力损害及超声乳化动力学参数之间的关系。
对51只眼(34例患者)的年龄相关性核性白内障进行超声乳化手术。使用光线追踪像差仪(iTrace视觉功能分析仪;Tracey Technologies公司,得克萨斯州休斯顿)测量晶状体功能障碍指数(0至10分)。使用旋转式Scheimpflug系统(Pentacam HR;德国韦茨拉尔Oculus Optikgeräte GmbH公司)评估平均晶状体密度(0至100),并使用晶状体混浊分类系统III(LOCS III)主观评估核混浊度评分。评估晶状体功能障碍的不同参数与术前矫正远视力(CDVA)和累积耗散能量(CDE)相关。
晶状体功能障碍指数与LOCS III核混浊度及Scheimpflug测量的平均密度之间呈负线性相关(分别为r = -0.728和r = -0.771;P均<0.01)。术前CDVA与Scheimpflug测量的晶状体核密度值(r = 0.612,P<0.01)和晶状体功能障碍指数评分A(r = -0.670,P<0.01)相关。CDE与晶状体功能障碍指数和Scheimpflug衍生的平均密度的相关性更强(分别为r = -0.744和r = 0.700;P均<0.01),而与LOCS III核混浊度的相关性较弱(r = 0.646,P<0.01)。
晶状体功能障碍指数与Scheimpflug测量的平均密度、主观晶状体分级及术前CDVA相关。该指标与超声乳化动力学的相关性也最高。仍需要与其他与视觉质量和损害相关的临床指标进行相关性研究。[《白内障与屈光手术杂志》。2017;33(2):79 - 83。]