Suppr超能文献

后房型有孔和无孔(ICL V4和ICL V4c)可植入式角膜接触镜植入术后穹窿早期变化及影响因素的比较

Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c).

作者信息

Chen Xun, Miao Huamao, Naidu Rajeev Krishnan, Wang Xiaoying, Zhou Xingtao

机构信息

Key Lab of Myopia, Ministry of Health, Shanghai, China.

EYE & ENT Hospital of Fudan University, Shanghai, China.

出版信息

BMC Ophthalmol. 2016 Sep 7;16(1):161. doi: 10.1186/s12886-016-0336-8.

Abstract

BACKGROUND

To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia.

METHODS

This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c intraocular lenses. We quantitatively assessed the postoperative values of vault and pupil size at 1 day, 1 week, and 1 month following implantation using a rotating Scheimpflug camera (Pentacam). We compared these postoperative values within and between the two groups and identified the factors affecting vault change.

RESULTS

The mean vaults at 1 day, 1 week, and 1 month following ICL V4 implantation were 303.68 ± 185.11, 517.89 ± 160.07 and 521.32 ± 155.72 μm respectively, and those following ICL V4c were 316.67 ± 186.89, 495.13 ± 180.84 and 510.77 ± 175.51 μm, respectively. There was a significant difference in vault between 1 day and 1 week postoperatively. There was a significant association between the vault change and the pupil size change in both groups from 1 day to 1 month postoperatively (Pearman correlation coefficient; ICL V4: r = 0.585, P = 0.001; ICL V4c: r = 0.588, P <0.001). The vault value 1 month after implantation of ICL V4 and ICL V4c was associated with the preoperative anterior chamber depth, horizontal corneal diameter, horizontal and vertical sulcus-to-sulcus.

CONCLUSIONS

Pupil movement is a critical factor in vault change, with increasing vault observed postoperatively from 1 day to 1 week associated with the declining effects of pharmacological miosis and increasing pupil size. The anterior chamber depth, horizontal corneal diameter, horizontal and vertical sulcus-to-sulcus show some correlation with vault.

摘要

背景

客观比较植入无中央孔(ICL V4)和有中央孔(ICL V4c)的可植入式胶原晶状体后,随着时间推移前房深度的早期变化,以及中高度近视患者前房深度变化的相关影响因素。

方法

这项前瞻性研究纳入了38例植入ICL V4人工晶状体的患者的38只眼和39例植入ICL V4c人工晶状体的患者的39只眼。我们使用旋转式Scheimpflug相机(Pentacam)在植入后1天、1周和1个月定量评估前房深度和瞳孔大小的术后值。我们比较了两组内和两组间的这些术后值,并确定了影响前房深度变化的因素。

结果

ICL V4植入后1天、1周和1个月时的平均前房深度分别为303.68±185.11、517.89±160.07和521.32±155.72μm,ICL V4c植入后的平均前房深度分别为316.67±186.89、495.13±180.84和510.77±175.51μm。术后1天和1周时前房深度有显著差异。两组术后1天至1个月期间,前房深度变化与瞳孔大小变化之间存在显著相关性(Pearman相关系数;ICL V4:r = 0.585,P = 0.001;ICL V4c:r = 0.588,P <0.001)。ICL V4和ICL V4c植入后1个月时的前房深度值与术前前房深度、角膜水平直径、水平和垂直睫状沟间距有关。

结论

瞳孔运动是前房深度变化的关键因素,术后1天至1周观察到前房深度增加与药物性瞳孔缩小作用减弱和瞳孔大小增加有关。前房深度、角膜水平直径、水平和垂直睫状沟间距与前房深度存在一定相关性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2dd2/5015244/3d8a1ef184f5/12886_2016_336_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验