Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany; Medical Faculty, Ludwig Maximilian University Munich, Bavariaring 19, 80336 Munich, Germany; Institute for Radiology, DONAUISAR Hospital Deggendorf-Dingolfing-Landau, Perlasberger Str. 41, 94469 Deggendorf, Germany.

出版信息

Eur J Radiol. 2023 Sep;166:110967. doi: 10.1016/j.ejrad.2023.110967. Epub 2023 Jul 16.

Abstract

PURPOSE

To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans.

METHODS

This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrast-enhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)) and on VNC series (CT-values(BP)) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values(BP), CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia).

RESULTS

A total of 329 patients (age 68 ± 12 years; 200 men) were included. CT-values(BP) showed a strong linear correlation to serum hemoglobin (r = 0.80, p <.001) and hematocrit (r = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (ΔHU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP) (all AUC's > 0.90).

CONCLUSIONS

The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.

摘要

目的

通过对比增强 PCD-CT 扫描,探讨 VNC 系列血池 CT 值与血清血红蛋白值之间的相关性,以检测肿瘤患者的贫血情况。

方法

本前瞻性研究(NCT04989192)纳入了 2021 年 8 月至 2022 年 1 月期间在新型 PCD-CT 系统上接受对比增强 CT 检查的连续肿瘤患者。全血细胞计数(CBC)和 CT 扫描采集之间的时间间隔不得超过 7 天。在 70keV VMI 系列(CT 值(BP))和 VNC 系列(CT 值(BP))上测量五个解剖位置(左心房、左心室、主肺动脉、升主动脉和降主动脉)的血池 CT 值,并对每位患者进行平均。进行 Pearson 相关分析和 ROC 分析,以确定 CT 值(BP)、CBC 参数与世界卫生组织(WHO)定义的贫血程度(无贫血、轻度贫血、中度贫血、重度贫血)之间的关系。

结果

共纳入 329 例患者(年龄 68±12 岁,男性 200 例)。CT 值(BP)与血清血红蛋白(r=0.80,p<.001)和红细胞压积(r=0.76,p<.001)呈强线性相关,且在女性和男性的贫血亚组之间存在显著差异(ΔHU:3.5-11.4;所有 p<.01)。ROC 分析显示,使用性别特异性 CT 值(BP)截断值,对识别无贫血、无贫血伴轻度贫血和重度贫血患者的诊断性能较高(所有 AUC>0.90)。

结论

PCD-CT 采集所固有的光谱信息允许以高诊断准确性检测和量化肿瘤患者增强 CT 采集的贫血情况。