Abstract

Standard urine culture (SUC) is the current standard method for confirmation of a urinary tract infection (UTI). SUC identifies microorganisms in urine samples and semi-quantifies these as colony-forming units (CFUs) ml-1. In contrast, quantitative multiplex polymerase chain reaction (q-MPCR) is a culture-independent assay in which the microbes are quantified by targeting genomic sequences and reported as cells ml-1, calculated from copies ml-1. Using serial dilutions within the 104-105 cells ml-1 range, the usual reporting range of SUC, this study compared the quantification results based on SUC and q-MPCR for four uropathogens with the control hemocytometer counts. The results revealed a linear relationship and a 1:1 correlation between the q-MPCR and SUC results. Additional q-MPCR quantification of 36 uropathogenic non-fastidious and fastidious bacteria and yeast indicated a reproducible linear correlation in a 1:1 manner with the control counts over a range of cell densities (103-106 cells ml-1). The results confirm that the quantifications by q-MPCR in cells ml-1 and by SUC in CFUs ml-1 are comparable and answer to the lingering question of how the results of these two methods correlate. Moreover, q-MPCR provided accurate quantification of various microorganisms over wider cell density ranges without the time required for microbial growth.

摘要

标准尿液培养(SUC)是目前确认尿路感染(UTI)的标准方法。SUC 可识别尿液样本中的微生物,并将其半定量为菌落形成单位(CFU)ml-1。相比之下,定量多重聚合酶链反应(q-MPCR)是一种非培养依赖的检测方法,其中通过靶向基因组序列来定量微生物,并以细胞 ml-1报告,从拷贝 ml-1计算得出。本研究使用 104-105 细胞 ml-1 范围内的系列稀释液,这是 SUC 的常规报告范围,将基于 SUC 和 q-MPCR 的四种尿路病原体的定量结果与对照血球计数仪计数进行了比较。结果显示,q-MPCR 和 SUC 结果之间存在线性关系和 1:1 相关性。对 36 种尿路非苛养和苛养细菌和酵母的额外 q-MPCR 定量表明,在细胞密度范围(103-106 细胞 ml-1)内,以 1:1 的方式与对照计数具有可重复的线性相关性。结果证实,q-MPCR 以细胞 ml-1 进行的定量和 SUC 以 CFU ml-1 进行的定量是可比的,并且回答了这两种方法的结果如何相关的遗留问题。此外,q-MPCR 无需微生物生长所需的时间即可在更宽的细胞密度范围内准确定量各种微生物。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验