Suppr超能文献

一项采用胸骨旁长轴切面二尖瓣M型运动测量评估左心室舒张功能的初步研究。

A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View.

作者信息

Park Chan-Ho, Yoon Hee, Jo Ik-Joon, Woo Sookyoung, Heo Sejin, Chang Hansol, Lee Guntak, Park Jong-Eun, Kim Taerim, Lee Se-Uk, Hwang Sung-Yeon, Cha Won-Chul, Shin Tae-Gun

机构信息

Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea.

Biomedical Statistics Center, Research Institute for Future Medicine, Samsung Medical Center; Seoul 06351, Republic of Korea.

出版信息

Diagnostics (Basel). 2023 Jul 19;13(14):2412. doi: 10.3390/diagnostics13142412.

Abstract

This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thirty healthy volunteers from a tertiary emergency department (ED) underwent M-mode measurements of the MV anterior leaflet in the PSLA view. EPSS, A-point septal separation (APSS), A-point opening length (APOL), and E-point opening length (EPOL) were measured in the PSLA view, along with the E and A velocities and e' velocity in the apical four-chamber view. Correlation analyses were performed to assess the relationship between M-mode and Doppler measurements, and the measurement time was evaluated. No significant correlations were found between M-mode and Doppler measurements in the study. However, M-mode measurements exhibited high reproducibility and faster acquisition, and the EPOL value consistently exceeded the APOL value, resembling the E and A pattern. These findings suggest that visually assessing the M-mode pattern on the MV anterior leaflet in the PSLA view may be a practical approach to estimating diastolic function in the ED. Further investigations with a larger and more diverse patient population are needed to validate these findings.

摘要

这项初步研究旨在开发一种新的、可靠且易于使用的方法,通过在胸骨旁长轴(PSLA)视图中对二尖瓣(MV)运动进行M型测量来评估舒张功能,类似于用于评估收缩功能的E点室间隔分离(EPSS)。来自一家三级急诊科(ED)的30名健康志愿者在PSLA视图下接受了MV前叶的M型测量。在PSLA视图中测量了EPSS、A点室间隔分离(APSS)、A点开口长度(APOL)和E点开口长度(EPOL),同时在心尖四腔视图中测量了E和A速度以及e'速度。进行相关性分析以评估M型测量与多普勒测量之间的关系,并对测量时间进行了评估。在该研究中,未发现M型测量与多普勒测量之间存在显著相关性。然而,M型测量具有高重复性且采集速度更快,并且EPOL值始终超过APOL值,类似于E和A模式。这些发现表明,在PSLA视图中目视评估MV前叶的M型模式可能是在急诊科评估舒张功能的一种实用方法。需要对更大且更多样化的患者群体进行进一步研究以验证这些发现。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cf8d/10378499/bea3fe945b0d/diagnostics-13-02412-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验