Suppr超能文献

[取出的喷丸处理接骨板的研究]

[Studies of explanted shot-peened osteosynthesis plates].

作者信息

Starker M, Ungethüm M, Zichner L

出版信息

Z Orthop Ihre Grenzgeb. 1986 May-Jun;124(3):350-4. doi: 10.1055/s-2008-1044574.

Abstract

Shot peening is a cold-working process to increase the fatigue life of osteosynthesis plates. Using ceramic particles for this process we observed no change in the corrosive properties of the plates. Up to now we implanted 37 shot peened osteosynthesis plates for fixation of intertrochanteric osteotomies. 13 plates were explanted after an average time of 14,2 months. We investigated the plates as well as the tissue surrounding the implants. Metallurgic specimens showed not so many pittings at the shot peened plates in the region of the screw hole as were seen at the polished plates after the same period of implantation. By histological investigation corrosive products or fretting particles were detected mostly in the region of the screws. Only a few metal particles were found in the region between the screw holes. Analysing the elements which were black or red-brown coloured in histological specimens by scanning electron microscopy we identified these particles as metal components. But there was a great difference in the relation of the particles found in the tissue compared to the components forming the plates alloy. This is due to the difference of distribution of the metal components at the surface of the implant in comparison with the central part of the plate. These austenitic stainless steels are protected by an enrichment of Cr in the surface layer. This could be shown in the shot peened plates as well as in the polished plates. The results of our investigations show a corrosive behaviour which is at least equal at both plates types in laboratory investigations as well as after implantations in men.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

喷丸处理是一种冷加工工艺,用于提高接骨板的疲劳寿命。在此过程中使用陶瓷颗粒时,我们观察到接骨板的腐蚀性能没有变化。到目前为止,我们已植入37块喷丸处理的接骨板用于转子间截骨术的固定。平均14.2个月后取出了13块接骨板。我们对接骨板以及植入物周围的组织进行了研究。金相标本显示,在植入相同时间后,喷丸处理的接骨板在螺丝孔区域的点蚀比抛光接骨板少。通过组织学研究,腐蚀产物或微动颗粒大多在螺丝区域被检测到。在螺丝孔之间的区域仅发现少量金属颗粒。通过扫描电子显微镜分析组织学标本中黑色或红棕色的元素,我们将这些颗粒鉴定为金属成分。但是,与构成接骨板合金的成分相比,在组织中发现的颗粒比例存在很大差异。这是由于植入物表面与接骨板中心部分的金属成分分布不同所致。这些奥氏体不锈钢通过表面层中Cr的富集得到保护。这在喷丸处理的接骨板和抛光接骨板中都得到了证实。我们的研究结果表明,在实验室研究以及人体植入后,两种类型的接骨板的腐蚀行为至少是相同的。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验