Suppr超能文献

Effect of heparinization of fluids infused through an umbilical artery catheter on catheter patency and frequency of complications.

作者信息

Rajani K, Goetzman B W, Wennberg R P, Turner E, Abildgaard C

出版信息

Pediatrics. 1979 Apr;63(4):552-6.

PMID:375178
Abstract

Heparinization of fluids (1 unit/ml) infused through an umbilical artery catheter (UAC) was efficacious in prolonging catheter patency in a double-blind, randomized, controlled clinical study. On the basis of life-table analysis, the half-life of catheter function was seven days in the heparinized group as compared with just over two days in the nonheparinized group (P less than .01). UAC occlusion occurred in 4 of 32 patients in the heparinized and 19 of 30 in the nonheparinized group (chi 2 = 17.6, P less than .01). Blood transfusions, number of arterial blood gases drawn through the UACs, and fluid infusion rates were not related to catheter occlusion. Heparinization of the UAC infusion did not alter the partial thromboplastin time or the incidence of catheter-related thromboembolic phenomena in the extremities. Heparinization of fluids infused through a UAC appears to be useful in the care of critically ill neonates.