Suppr超能文献

Ex-PRESS P-200微型分流器植入术与标准小梁切除术治疗开角型青光眼的比较:四年随访

Comparison of Ex-PRESS P-200 mini-shunt implantation and standard trabeculectomy for open-angle glaucoma: four-year follow-up.

作者信息

Nicula Cristina, Nicula Dorin, Rednik Anca, Bulboacă Adriana Elena, Bolboacă Sorana D

机构信息

Department of Ophthalmology, Iuliu Haţieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.

Oculens Clinic, Calea Turzii, Cluj-Napoca, Romania.

出版信息

Arch Med Sci. 2019 Nov 25;19(4):1069-1079. doi: 10.5114/aoms.2019.89971. eCollection 2023.

Abstract

INTRODUCTION

The study aimed to evaluate the efficacy and safety in 4-year follow-up of Ex-PRESS P-200 mini-shunt implantation versus standard trabeculectomy.

MATERIAL AND METHODS

A single-center retrospective study on patients diagnosed with open-angle glaucoma with failed medical treatment and who underwent Ex-PRESS device implantation or standard trabeculectomy was conducted. Seventy-three eyes were included in the analysis, 33 with Ex-PRESS P-200 implantation and 40 with standard trabeculectomy.

RESULTS

Significant decreases in the intraocular pressure (IOP) were observed after surgery and at all follow-ups in both groups ( < 0.001) with no significant difference between the two groups ( > 0.40). No significant differences with regard to post-operative medications were observed ( > 0.10). Excepting the 3-year follow-up, when just a borderline significant difference regarding the visual acuity between the Ex-PRESS and standard trabeculectomy group was observed ( = 0.0504), the Ex-PRESS groups showed significantly better visual acuity at 6 weeks ( = 0.0324), 1 year ( = 0.0168), 2 years ( = 0.0162), and 4 years ( = 0.0111). Hypotony occurred more frequently among the Ex-PRESS group, while cataract occurred more frequently among those with standard trabeculectomy, without significant differences between groups ( > 0.09). No difference in hazard of failure was observed between interventions (HR = 0.72, = 0.523).

CONCLUSIONS

Both procedures provided good control of IOP and decreased the number of postoperative medications. The advantage of the Ex-PRESS shunt is the better visual acuity, but its main limitation is the cost.

摘要

引言

本研究旨在评估Ex-PRESS P-200微型分流植入术与标准小梁切除术4年随访期内的疗效和安全性。

材料与方法

对诊断为药物治疗失败的开角型青光眼且接受Ex-PRESS装置植入术或标准小梁切除术的患者进行单中心回顾性研究。73只眼纳入分析,其中33只眼接受Ex-PRESS P-200植入术,40只眼接受标准小梁切除术。

结果

两组术后及各随访期眼压均显著降低(<0.001),两组间无显著差异(>0.40)。术后用药方面未观察到显著差异(>0.10)。除3年随访时Ex-PRESS组与标准小梁切除术组在视力方面仅观察到临界显著差异(=0.0504)外,Ex-PRESS组在6周(=0.0324)、1年(=0.0168)、2年(=0.0162)和4年(=0.0111)时视力显著更好。低眼压在Ex-PRESS组中更频繁发生,而白内障在标准小梁切除术患者中更频繁发生,两组间无显著差异(>0.09)。两种干预措施在失败风险方面未观察到差异(HR = 0.72,=0.523)。

结论

两种手术均能良好控制眼压并减少术后用药数量。Ex-PRESS分流术的优势在于视力更好,但其主要局限在于成本。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d56c/10408006/f1600d8b5190/AMS-19-4-113238-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验