镫骨切除术中砧骨长突直径的重要性——来自体内研究的新发现

Importance of Diameter of Long Process of Incus in Stapedotomy-New Findings From In Vivo Study.

作者信息

Anand Veluswamy, Anand Aiswarya, Janarthanan Sridurga, Francis Sebina

机构信息

Department of ENT, MCV ENT CLINIC, Tamil Nadu, India.

出版信息

Int Arch Otorhinolaryngol. 2023 Aug 4;27(3):e385-e392. doi: 10.1055/s-0043-1770995. eCollection 2023 Jul.

Abstract

Stapes surgery for otosclerosis is a precise surgical procedure. To achieve excellent hearing results, a firm and stable attachment of the prosthesis to the long process of incus (LPI) is necessary. The present study provides details on the attachment site in two dimensions to choose an appropriate prosthesis and to ensure firm attachment for better surgical outcomes.  To study the diameter of the LPI and its relevance in determining the piston, used in stapes surgery by an in vivo method.  This study was conducted in 41 patients who underwent stapedotomy, where both Anteroposterior (AP) and Mediolateral (ML) diameters of the LPI were measured at the site of attachment of the piston using specially designed instruments, intraoperatively. Radiological data were obtained to measure the LPI diameter from the normal ears of 46 patients. It was measured from both the right and left side, hence 92 LPI diameters were obtained.  The most commonly used site for prosthesis attachment is between 1-1.5 mm away from the tip of the LPI. We found great variability in the diameters of LPI in the attachment site, with the AP diameter ranging between 0.6 -1.5mm and the ML diameter ranging between 0.5mm-1.2 mm.  Pistons by design have characteristics of gripping incus that will vary between types. Based on LPI dimensions, ideal piston types with appropriate inner loop diameters are suggested in this study. HRCT before surgery should include measurements of the LPI as a guide to the choice of the prosthesis during surgery.

摘要

镫骨硬化症的镫骨手术是一种精确的外科手术。为了获得出色的听力效果,将假体牢固稳定地附着于砧骨长突(LPI)是必要的。本研究提供了二维附着部位的详细信息,以选择合适的假体并确保牢固附着,从而实现更好的手术效果。

通过体内方法研究LPI的直径及其在确定镫骨手术中使用的活塞方面的相关性。

本研究对41例行镫骨切开术的患者进行,术中使用专门设计的器械在活塞附着部位测量LPI的前后径(AP)和内外径(ML)。从46例患者的正常耳获取放射学数据以测量LPI直径。由于对左右两侧均进行了测量,因此共获得92个LPI直径数据。

假体最常用的附着部位是距离LPI尖端1 - 1.5毫米之间。我们发现附着部位的LPI直径差异很大,AP直径在0.6 - 1.5毫米之间,ML直径在0.5毫米 - 1.2毫米之间。

不同类型的活塞在设计上具有不同的夹持砧骨的特性。基于LPI尺寸,本研究建议了具有合适内环直径的理想活塞类型。术前的高分辨率计算机断层扫描(HRCT)应包括LPI的测量,作为手术中选择假体的指导。