The success of the machine perfusion of pig livers used for preclinical research depends on organ quality and availability. In this study, we investigated whether livers obtained from slaughterhouses are suitable and equivalent to livers obtained from laboratory pigs.
Livers were obtained from slaughterhouse pigs stunned by electrocution or CO inhalation and from laboratory pigs. For the latter group, 45 minutes of warm ischemia was mimicked for a subgroup, ensuring a valid comparison with slaughterhouse-derived livers.
Livers from CO-stunned pigs showed lower indocyanine green clearance and bile production, higher blood lactate and potassium concentrations, and higher alanine aminotransferase activities than electrically stunned pigs. Furthermore, livers from electrically stunned pigs, and livers from laboratory pigs, subjected or not to warm ischemia, showed similar performance in terms of perfusion and metabolism.
For an liver model generated using slaughterhouse pigs, electrical stunning is preferable to CO stunning. Livers from electrically stunned slaughterhouse pigs performed similarly to laboratory pig livers. These findings support the use of livers from electrically stunned slaughterhouse pigs, which may therefore provide an alternative to livers obtained from laboratory pigs, consistent with the principle of the 3Rs.
用于临床前研究的猪离体肝脏机械灌注的成功与否取决于器官的质量和可用性。本研究旨在探讨从屠宰场获取的肝脏是否适合且等同于从实验猪获取的肝脏。
从电击或 CO 吸入致晕的屠宰场猪以及从实验室猪获取肝脏。对于后者,模拟 45 分钟的热缺血,以与屠宰场来源的肝脏进行有效比较。
与电击致晕的猪相比,CO 致晕的猪的吲哚菁绿清除率和胆汁生成较低,血乳酸和钾浓度较高,丙氨酸氨基转移酶活性较高。此外,电击致晕的猪,以及是否经历热缺血的实验室猪的肝脏,在灌注和代谢方面表现相似。
对于使用屠宰场猪建立的离体肝脏模型,电击致晕优于 CO 致晕。电击致晕的屠宰场猪的肝脏与实验室猪的肝脏表现相似。这些发现支持使用电击致晕的屠宰场猪的肝脏,这可能为符合 3R 原则的从实验室猪获取肝脏提供替代方案。