一种用于评估全肘关节置换术中肱骨假体旋转的软组织标志。

A Soft-Tissue Landmark to Assess Humeral Component Rotation in Total Elbow Arthroplasty.

作者信息

Azimi Hassan, Ahmad Farhan, Sabet Andre D, Cohen Mark, Maschke Steve, Wysocki Robert, Simcock Xavier

机构信息

Department of Orthopedic Surgery, Rush University Medical Center, Chicago, USA.

Department of Orthopedic Surgery, Cleveland Clinic Foundation, Cleveland, USA.

出版信息

Cureus. 2023 Jul 11;15(7):e41729. doi: 10.7759/cureus.41729. eCollection 2023 Jul.

Abstract

HYPOTHESIS

Assessing the rotational alignment of the humeral component during total elbow arthroplasty is dependent upon bony landmarks that can be absent or altered in cases of distal humerus fractures, revision arthroplasty, severe bone loss, or deformity. We hypothesize that the intermuscular septum can be used as a reliable soft-tissue landmark to set the rotation of the humeral component intra-operatively when previously described bony landmarks are not reliable or present.

MATERIALS AND METHODS

Forty-eight unpaired cadaveric human subjects (mean age and standard deviation 63 ± 12 years; 24 males, 24 females) underwent computed tomography (CT) scans. The geometric centers of the trochlea and capitellum were assessed, and the line through these two points was set as the flexion-extension axis (FEA) of the elbow. The intermuscular septum axis (IMSA) was drawn proximal to the olecranon fossa and at least 4 cm proximal to the most distal point of the articular surface, where the posterior humeral cortex was flat. The angles between the FEA and IMSA were calculated and compared using a two-tailed t-test. Regression analysis was used to assess the inter- and intra-observer reliability of the IMSA.

RESULTS

The IMSA was externally rotated 10.3° ± 2.8 compared to the FEA (p < 0.001 and confidence interval (CI) of 2.8 with α set to 0.01). The inter- and intra-observer reliability of the IMSA was high, with an R-value of 0.91 and 0.97, respectively.

CONCLUSIONS

The intermuscular septum can be used as a soft-tissue landmark to set humeral component rotation and is 10.3° externally rotated with respect to the FEA of the ulnohumeral joint.

摘要

假设

在全肘关节置换术中评估肱骨组件的旋转对线依赖于骨性标志,但在肱骨远端骨折、翻修置换术、严重骨丢失或畸形的情况下,这些骨性标志可能缺失或改变。我们假设,当先前描述的骨性标志不可靠或不存在时,肌间隔可作为可靠的软组织标志,在术中确定肱骨组件的旋转。

材料与方法

对48例未配对的人体尸体标本(平均年龄和标准差63±12岁;男性24例,女性24例)进行计算机断层扫描(CT)。评估滑车和肱骨小头的几何中心,并将通过这两点的线设定为肘关节的屈伸轴(FEA)。肌间隔轴(IMSA)在鹰嘴窝近端、关节面最远端至少4 cm近端绘制,此处肱骨后皮质平坦。使用双尾t检验计算并比较FEA与IMSA之间的角度。采用回归分析评估IMSA在观察者间和观察者内的可靠性。

结果

与FEA相比,IMSA向外旋转10.3°±2.8°(p<0.001,α设定为0.01时的置信区间(CI)为2.8)。IMSA在观察者间和观察者内的可靠性较高,R值分别为0.91和0.97。

结论

肌间隔可作为确定肱骨组件旋转的软组织标志,相对于尺肱关节的FEA向外旋转10.3°。