Suppr超能文献

Wire ThRoUgh Snare Twice (Wire TRUST) 技术:一种通过股静脉途径提取心内植入式电子器械时,用于抓握无法触及的导线两端的新方法。

Wire ThRoUgh Snare Twice (Wire TRUST) technique: A novel method to grasp a lead with inaccessible ends as a supportive femoral approach for transvenous lead extraction.

机构信息

Asia Medical Group, Department of Cardiology, Sapporo CardioVascular Clinic, Sapporo Heart Center, Sapporo, Japan.

Asia Medical Group, Department of Clinical Engineering, Sapporo CardioVascular Clinic, Sapporo Heart Center, Sapporo, Japan.

出版信息

J Cardiovasc Electrophysiol. 2023 Sep;34(9):1990-1995. doi: 10.1111/jce.16041. Epub 2023 Aug 14.

Abstract

INTRODUCTION

Transvenous lead extraction (TLE) is a crucial procedure for managing cardiac implantable electronic devices. The use of a combined superior and femoral approach has been found to enhance the success rate of TLE. This report introduces a novel technique, named "Wire ThRoUgh Snare Twice" (Wire TRUST), for effectively grasping a lead without a free end during TLE.

METHOD

The Wire TRUST technique was applied in a case involving a 49-year-old male patient requiring TLE due to electrical artifact on the right ventricular (RV) lead, replacement of the RV lead, and pacemaker generator exchange. The Wire TRUST technique involved the insertion of a 4-Fr pigtail catheter and a 6-Fr snare catheter through the 14-Fr sheath inserted from the right common femoral vein. The 4-Fr pigtail catheter was hooked to the RV lead under multidirectional fluoroscopic guidance in the right atrium. The 0.014-in. guidewire was advanced through the pigtail catheter, crossing the RV lead until reaching the inferior vena cava. Subsequently, the distal end of the 0.014-in. guidewire was captured using a snare and pulled, facilitating externalization of the guidewire. After externalization, both ends of the 0.014-in. guidewire were passed through the snare outside the body and reinserted into the 14-Fr sheath. By simultaneously advancing and closing the snare while applying tension to the 0.014-in. guidewire, a secure grip on the lead without free ends was achieved.

RESULTS

The Wire TRUST technique enabled successful lead extraction and replacement without any complications. The technique facilitated the co-axial alignment of the powered sheath with the RV lead, ensuring safe and efficient extraction.

CONCLUSION

The Wire TRUST technique presents a novel and effective approach for grasping leads with inaccessible ends during TLE.

摘要

简介

经静脉导线拔除术(TLE)是管理心脏植入式电子设备的关键程序。已发现联合使用上腔静脉和股静脉入路可提高 TLE 的成功率。本报告介绍了一种新的技术,称为“Wire ThRoUgh Snare Twice”(Wire TRUST),用于在 TLE 期间有效抓取无游离端的导线。

方法

Wire TRUST 技术应用于一位 49 岁男性患者,因右心室(RV)导线出现电干扰、更换 RV 导线和起搏器发生器更换而需要 TLE。Wire TRUST 技术涉及通过从右股总静脉插入的 14Fr 鞘管插入 4Fr 猪尾导管和 6Fr 圈套导管。在右心房的多方向透视引导下,将 4Fr 猪尾导管钩住 RV 导线。将 0.014 英寸导丝穿过猪尾导管推进,穿过 RV 导线,直至到达下腔静脉。随后,使用圈套捕捉 0.014 英寸导丝的远端并拉动,使导丝向外引出。导丝向外引出后,将 0.014 英寸导丝的两端穿过圈套并重新插入 14Fr 鞘管。通过同时推进和关闭圈套并对 0.014 英寸导丝施加张力,实现了对无游离端的导线的牢固抓取。

结果

Wire TRUST 技术成功地进行了导线拔除和更换,没有任何并发症。该技术促进了带电器械鞘与 RV 导线的同轴对准,确保了安全高效的拔除。

结论

Wire TRUST 技术为 TLE 期间抓取无法触及末端的导线提供了一种新颖而有效的方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验