Engseth Lars H W, Grønsund Jørgen, Aunan Eirik, Brattgjerd Jan Egil, Schulz Anselm, Moatshe Gilbert, Röhrl Stephan M
Department of Orthopaedics, Oslo University Hospital Ullevål (OUH), P.O Box 4956, Nydalen, Oslo, 0424, Norway.
Department of Surgery, Innlandet Hospital Trust, Lillehammer, Norway.
J Exp Orthop. 2023 Aug 16;10(1):83. doi: 10.1186/s40634-023-00643-7.
Ligament balancing is a prerequisite for good function and survival in total knee arthroplasty (TKA). Various balancing techniques exist, but none have shown superior results. The pie-crusting technique by Bellemans of the medial collateral ligament is commonly utilized; however, it can be difficult to achieve repeatable ligament lengthening with this technique. Therefore, we invented a novel instrument to standardize the pie-crusting technique of the superficial and deep medial collateral ligament (hereafter MCL). The purpose was to examine if pie-crusting with the instrument could produce repeatable ligament lengthening.
The MCL was isolated in 16 human cadaveric knees, and subjected to axial tension. The instrument was composed of a specific grid of holes in rows, used to guide sequential pie-crusting puncturing of the MCL with a Ø1.6 mm end-cutting cannula. Ligament lengthening was measured after each row of punctures. Regression analysis was performed on the results.
Mean lengthening ± SD in human cadaveric MCL for puncturing of row 1 in the instrument was 0.06 ± 0.09 mm, 0.06 ± 0.04 mm for row 2, 0.09 ± 0.08 mm for row 3, 0.06 ± 0.05 mm for row 4 and 0.06 ± 0.04 mm for row 5, giving a mean total lengthening of 0.33 ± 0.20 mm. Linear regression revealed that MCLs were repeatably lengthened by 0.07 mm per row when punctured using the instrument.
MCLs showed linear lengthening in human cadavers for subsequent use of the instrument. Our instrument shows promising results for repeatable ligament lengthening.
韧带平衡是全膝关节置换术(TKA)获得良好功能及假体存活的前提条件。现有多种平衡技术,但尚无一种显示出更优的效果。Bellemans提出的内侧副韧带“碎皮术”技术应用广泛;然而,采用该技术难以实现可重复的韧带延长。因此,我们发明了一种新型器械,以使浅层和深层内侧副韧带(以下简称MCL)的“碎皮术”技术标准化。目的是检验使用该器械进行“碎皮术”是否能实现可重复的韧带延长。
在16具人类尸体膝关节中分离出MCL,并施加轴向张力。该器械由成排的特定孔格组成,用于引导使用直径1.6 mm的端切套管针依次对MCL进行“碎皮术”穿刺。每排穿刺后测量韧带延长情况。对结果进行回归分析。
在人类尸体MCL中,器械第1排穿刺后的平均延长量±标准差为0.06±0.09 mm,第2排为0.06±0.04 mm,第3排为0.09±0.08 mm,第4排为0.06±0.05 mm,第5排为0.06±0.04 mm,平均总延长量为0.33±0.20 mm。线性回归显示,使用该器械穿刺时,MCL每排可重复延长0.07 mm。
在人类尸体中,MCL使用该器械后呈线性延长。我们的器械在实现可重复的韧带延长方面显示出有前景的结果。