Suppr超能文献

婴幼儿髋关节超声中的软骨-骨边界:髋关节发育不良科研出版物准确性不可或缺的试金石。

Chondro-osseous border in baby hip ultrasonography for developmental dysplasia of the hip: an indispensable litmus paper for the accuracy of scientific publications.

机构信息

Vioapeikonisi Imaging Lab, Arkoleontos 9 Street, 71202, Heraklion, Crete, Greece.

Department of Orthopaedics, University Hospital Waterford, Waterford, Ireland.

出版信息

J Ultrasound. 2024 Jun;27(2):275-279. doi: 10.1007/s40477-023-00821-4. Epub 2023 Aug 20.

Abstract

PURPOSE

The aim of our study was to use the chondro-osseous border (COB) as an indispensable assessment criterion to evaluate the quality of baby hip ultrasonography (US) images in the literature pertaining to the application of Graf's technique.

MATERIALS AND METHODS

Our literature review search yielded 144 articles. Of these, 41 contained images that were stated to be based on the application of Graf's technique. Two reviewers, a radiologist and an orthopaedic surgeon, both course instructors for the use of baby hip US for developmental dysplasia of the hip (DDH), independently evaluated the articles to assess the diagnostic validity of the published images on the basis of a single criterion: the identification of the COB.

RESULTS

Of the 41 articles which were analyzed, 15 contained images without a COB, which corresponds to 36% (roughly, one out of three). Articles from countries where universal screening is performed (Germany, Italy, Switzerland, Mongolia) were all correct. All the articles from Turkey, a country which has made significant contribution with published material about Graf's technique over many years, and most of the articles from China (80%), where Graf's technique has become popular in recent years, contained correct images.

CONCLUSION

Published literature lacks strict criteria for the publication of correct images corresponding to Graf's technique in baby hip US. This fact raises concerns about the quality of published material (and, as a corollary, the quality of clinical application of the technique) and should have ramifications on scientific journal policies regarding the publication of such manuscripts.

摘要

目的

本研究旨在将骺-软骨交界(COB)作为评估 Graf 技术应用文献中婴儿髋关节超声(US)图像质量的不可或缺的评估标准。

材料与方法

我们的文献综述搜索得到了 144 篇文章。其中 41 篇文章包含了据称基于 Graf 技术应用的图像。两位审稿人,一位放射科医生和一位矫形外科医生,都是髋关节发育不良(DDH)婴儿髋关节 US 使用课程的讲师,他们根据单一标准(COB 的识别)独立评估了这些文章,以评估已发表图像的诊断有效性。

结果

在分析的 41 篇文章中,有 15 篇文章没有 COB,占 36%(大致为三分之一)。在德国、意大利、瑞士、蒙古等开展普遍筛查的国家的文章都是正确的。多年来发表了大量关于 Graf 技术文献的土耳其的所有文章,以及近年来 Graf 技术在婴儿髋关节 US 中变得流行的中国的大多数文章(80%)都包含了正确的图像。

结论

发表的文献缺乏 Graf 技术婴儿髋关节 US 正确图像发表的严格标准。这一事实引起了对发表材料质量的关注(以及技术临床应用质量的关注),并应影响科学期刊关于此类手稿发表的政策。

相似文献

7
Ultrasonography in developmental hip dysplasia.发育性髋关节发育不良的超声检查
J Pediatr Orthop. 1995 Jan-Feb;15(1):101-4. doi: 10.1097/01241398-199501000-00022.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验