Xu Hanyang, Huang Jiabo, Tian Wenchao, Li Zhao
School of Electro-Mechanical Engineering, Xidian University, Xi'an 710071, China.
Micromachines (Basel). 2023 Jul 26;14(8):1498. doi: 10.3390/mi14081498.
In high-integration electronic components, the insulated-gate bipolar transistor (IGBT) power module has a high working temperature, which requires reasonable thermal analysis and a cooling process to improve the reliability of the IGBT module. This paper presents an investigation into the heat dissipation of the integrated microchannel cooling plate in the silicon carbide IGBT power module and reports the impact of the BL series micropump on the efficiency of the cooling plate. The IGBT power module was first simplified as an equivalent-mass block with a mass of 62.64 g, a volume of 15.27 cm, a density of 4.10 g/cm, and a specific heat capacity of 512.53 J/(kg·K), through an equivalent method. Then, the thermal performance of the microchannel cooling plate with a main channel and a secondary channel was analyzed and the design of experiment (DOE) method was used to provide three factors and three levels of orthogonal simulation experiments. The three factors included microchannel width, number of secondary inlets, and inlet diameter. The results show that the microchannel cooling plate significantly reduces the temperature of IGBT chips and, as the microchannel width, number of secondary inlets, and inlet diameter increase, the junction temperature of chips gradually decreases. The optimal structure of the cooling plate is a microchannel width of 0.58 mm, 13 secondary inlets, and an inlet diameter of 3.8 mm, and the chip-junction temperature of this structure is decreased from 677 °C to 77.7 °C. In addition, the BL series micropump was connected to the inlet of the cooling plate and the thermal performance of the microchannel cooling plate with a micropump was analyzed. The micropump increases the frictional resistance of fluid flow, resulting in an increase in chip-junction temperature to 110 °C. This work demonstrates the impact of micropumps on the heat dissipation of cooling plates and provides a foundation for the design of cooling plates for IGBT power modules.
在高集成度电子元件中,绝缘栅双极型晶体管(IGBT)功率模块工作温度较高,这就需要进行合理的热分析和冷却处理,以提高IGBT模块的可靠性。本文对碳化硅IGBT功率模块中集成微通道冷却板的散热情况展开研究,并报告了BL系列微型泵对冷却板效率的影响。首先,通过等效方法将IGBT功率模块简化为一个等效质量块,其质量为62.64克,体积为15.27立方厘米,密度为4.10克/立方厘米,比热容为512.53焦/(千克·开尔文)。然后,对具有主通道和次通道的微通道冷却板的热性能进行分析,并采用实验设计(DOE)方法进行三因素三水平的正交模拟实验。这三个因素包括微通道宽度、次入口数量和入口直径。结果表明,微通道冷却板能显著降低IGBT芯片的温度,并且随着微通道宽度、次入口数量和入口直径的增加,芯片的结温逐渐降低。冷却板的最优结构为微通道宽度0.58毫米、13个次入口、入口直径3.8毫米,此结构的芯片结温从677℃降至77.7℃。此外,将BL系列微型泵连接到冷却板的入口,并分析了带有微型泵的微通道冷却板的热性能。微型泵增加了流体流动的摩擦阻力,导致芯片结温升高至110℃。这项工作展示了微型泵对冷却板散热的影响,为IGBT功率模块冷却板的设计提供了依据。