Abstract

BACKGROUND

This study aimed to compare the complication rates of epithelium-off corneal cross-linking (epi-off CXL) performed in an office-based setting with those of epi-off CXL performed in an operating room.

METHODS

A retrospective cohort study, comprising 501 consecutive epi-off CXL procedures, performed in a non-sterile procedure room without laminar flow ventilation at the ELZA Institute in Zurich, Switzerland, between November 2015 and October 2021, was conducted.

RESULTS

No cases of postoperative infectious keratitis were observed, while sterile infiltrates occurred in 10 out of 501 (2.00%) patients, all of whom responded well to topical steroid therapy. Delayed epithelialization (> 7 days) occurred in 14 out of 501 (2.79%) patients. No other adverse events were noted.

CONCLUSIONS

Office-based epi-off CXL does not appear to be associated with an increased risk of complications when compared to operating room settings.

摘要

背景

本研究旨在比较在门诊环境中进行的去上皮角膜交联术(epi-off CXL)与在手术室中进行的epi-off CXL的并发症发生率。

方法

进行了一项回顾性队列研究,纳入了2015年11月至2021年10月期间在瑞士苏黎世的ELZA研究所的非无菌、无层流通风的手术室内连续进行的501例epi-off CXL手术。

结果

未观察到术后感染性角膜炎病例,501例患者中有10例(2.00%)出现无菌性浸润,所有患者局部使用类固醇治疗后反应良好。501例患者中有14例(2.79%)出现上皮化延迟(>7天)。未发现其他不良事件。

结论

与手术室环境相比,门诊epi-off CXL似乎不会增加并发症风险。

相似文献

6
Corneal Cross-linking at the Slit Lamp.角膜交联术在裂隙灯下进行。
J Refract Surg. 2021 Feb 1;37(2):78-82. doi: 10.3928/1081597X-20201123-02.

本文引用的文献

6
Corneal Cross-linking at the Slit Lamp.角膜交联术在裂隙灯下进行。
J Refract Surg. 2021 Feb 1;37(2):78-82. doi: 10.3928/1081597X-20201123-02.
9
keratitis after corneal crosslinking.角膜交联术后的角膜炎
Am J Ophthalmol Case Rep. 2020 Jan 31;17:100616. doi: 10.1016/j.ajoc.2020.100616. eCollection 2020 Mar.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验