Abstract

OBJECTIVE

To determine the incidence and predictors of true arrhythmia in pediatric patients presenting with concerns about smartwatch cardiac data.

STUDY DESIGN

Single-center, retrospective cohort study of children aged 10-18 years who had presented to a pediatric cardiology clinic between January 2018 and December 2021 with concerns related to smartwatch cardiac data. The primary study outcome was diagnosis of arrhythmia based on clinical evaluation or documentation of arrhythmia by clinical testing.

RESULTS

There were 126 patients (mean age 15.6 ± 2.4 years) who presented with a smartwatch-based rhythm concern, with tachycardia in 89%. In all, 19 of 126 (15%) patients were diagnosed with true arrhythmia. The odds of a true arrhythmia diagnosis with symptoms vs no symptoms were 3.2 (95% CI 0.7-14.5), and with heart rate (HR) ≥190 beats/min vs HR <190 beats/min, it was 14.3 (95% CI 3.8-52.8). The positive predictive value of HR ≥190 beats/min and symptoms together to predict arrhythmia was only 39% (95% CI 28-52). The negative predictive value for arrhythmia having neither symptoms nor HR >190 was 95% (95% CI 75-99).

CONCLUSION

The likelihood of a true arrhythmia in pediatric patients presenting with a smartwatch-based HR concern was low. Rarely, smartwatch electrograms or trend data were sufficient for arrhythmia diagnosis.

摘要

目的

确定因智能手表心脏数据问题就诊的儿科患者中真性心律失常的发生率和预测因素。

研究设计

对 2018 年 1 月至 2021 年 12 月期间因智能手表心脏数据相关问题就诊于儿科心脏病学诊所的 10-18 岁儿童进行单中心回顾性队列研究。主要研究结局是根据临床评估或临床检查记录的心律失常诊断为心律失常。

结果

共有 126 例(平均年龄 15.6±2.4 岁)因智能手表节律问题就诊,其中心动过速 89%。总共 126 例患者中有 19 例(15%)被诊断为真性心律失常。有症状与无症状患者的真性心律失常诊断的优势比为 3.2(95%CI 0.7-14.5),心率(HR)≥190 次/分与 HR<190 次/分患者的优势比为 14.3(95%CI 3.8-52.8)。HR≥190 次/分和症状同时预测心律失常的阳性预测值仅为 39%(95%CI 28-52)。既无症状又无 HR>190 的心律失常的阴性预测值为 95%(95%CI 75-99)。

结论

因智能手表 HR 问题就诊的儿科患者发生真性心律失常的可能性较低。很少情况下,智能手表心电图或趋势数据足以诊断心律失常。