• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Validation of quantitative intraoperative transesophageal echocardiography.

作者信息

Konstadt S N, Thys D, Mindich B P, Kaplan J A, Goldman M

出版信息

Anesthesiology. 1986 Oct;65(4):418-21. doi: 10.1097/00000542-198610000-00012.

DOI:10.1097/00000542-198610000-00012
PMID:3767041
Abstract

Transesophageal echocardiography (TEE) is a new monitoring technique that images the heart and provides information on regional wall motion and left ventricular filling. However, despite its potential for inaccuracy due to its retrocardiac position and angulation, TEE has not been validated by another imaging technique. Using direct on-heart echocardiography (OHE) as a standard, the authors evaluated the ability of TEE to measure accurately left ventricular end-diastolic area (EDa), end-systolic area (ESa), and ejection fraction area (EFa). Ten patients with coronary artery disease without evidence of valvular dysfunction undergoing myocardial revascularization were studied. A Diasonics 3.5 MHz two-dimensional TEE probe was introduced into each patient's esophagus and positioned to obtain a view equivalent to the parasternal short-axis projection. A similar view was obtained by OHE using a sterilely prepared 3 MHz ATL probe placed on either the pericardium or epicardium. In each patient, immediately prior to and after pericardiotomy, both transesophageal and on-heart short-axis views at the level of the papillary muscles were obtained. Using a dedicated Diasonics computer echoanalyzer, EDa and ESa from four consecutive cardiac cycles were outlined with a light pen and averaged. EFa was calculated by the formula EFa = (EDa - ESa)/EDa. Seventeen comparable transesophageal and on-heart echocardiograms were obtained. ESa by TEE correlated well with ESa by OHE (15.13 +/- 9.62 cm2 vs. 14.92 +/- 10.53 cm2; r = 0.94). Similar results were obtained for EDa (27.75 +/- 9.88 cm2 vs. 30.40 +/- 13.99 cm2; r = 0.88) and EFa (0.49 +/- 0.17 vs. 0.54 +/- 0.13; r = 0.92). filling and ejection.

摘要

相似文献

1
Validation of quantitative intraoperative transesophageal echocardiography.
Anesthesiology. 1986 Oct;65(4):418-21. doi: 10.1097/00000542-198610000-00012.
2
Comparison of transesophageal echocardiographic and scintigraphic estimates of left ventricular end-diastolic volume index and ejection fraction in patients following coronary artery bypass grafting.
Anesthesiology. 1990 Apr;72(4):607-12. doi: 10.1097/00000542-199004000-00005.
3
Detection of myocardial ischemia by transesophageal echocardiographically determined changes in left ventricular area in patients undergoing coronary artery bypass surgery.经食管超声心动图测定冠状动脉搭桥手术患者左心室面积变化以检测心肌缺血
J Clin Anesth. 1997 Aug;9(5):388-93. doi: 10.1016/s0952-8180(97)00067-6.
4
Automated real-time analysis of intraoperative transesophageal echocardiograms.
Anesthesiology. 1993 Mar;78(3):477-85. doi: 10.1097/00000542-199303000-00011.
5
The normal pericardium does not affect left ventricular function.正常的心包不影响左心室功能。
J Cardiothorac Anesth. 1987 Aug;1(4):284-8. doi: 10.1016/s0888-6296(87)80038-8.
6
[Transesophageal echocardiography during coronary bypass surgery].
Kyobu Geka. 1990 Jan;43(1):31-5.
7
Evaluation of intraoperative transesophageal two-dimensional echocardiography.术中经食管二维超声心动图评估
Anesthesiology. 1987 Jan;66(1):64-8. doi: 10.1097/00000542-198701000-00012.
8
Transesophageal echocardiography in myocardial revascularization: I. Accuracy of intraoperative real-time interpretation.经食管超声心动图在心肌血运重建中的应用:I. 术中实时解读的准确性
Anesth Analg. 1996 Jun;82(6):1132-8. doi: 10.1097/00000539-199606000-00006.
9
Measurement of left ventricular contractility using transesophageal echocardiography in patients undergoing coronary artery bypass grafting. The Study of Perioperative Ischemia (SPI) Research Group.在接受冠状动脉搭桥手术的患者中使用经食管超声心动图测量左心室收缩功能。围手术期缺血研究(SPI)研究小组。
Am Heart J. 1991 Oct;122(4 Pt 1):1041-9. doi: 10.1016/0002-8703(91)90470-3.
10
Intraoperative transesophageal echocardiography for the detection of cardiac preload changes induced by transfusion and phlebotomy in pediatric patients.
Anesthesiology. 1993 Jul;79(1):10-5. doi: 10.1097/00000542-199307000-00004.

引用本文的文献

1
An introduction to transoesophageal echocardiography: II. Clinical applications.经食管超声心动图学概论:II. 临床应用
Can J Anaesth. 1996 Mar;43(3):278-94. doi: 10.1007/BF03011745.
2
Transvenous mitral commissurotomy examined with transesophageal echocardiography.经食管超声心动图检查经静脉二尖瓣交界切开术。
Heart Vessels. 1987;3(4):209-13. doi: 10.1007/BF02058313.
3
Transesophageal echocardiographic assessment of left ventricular function.经食管超声心动图对左心室功能的评估
Int J Card Imaging. 1989;5(1):63-70. doi: 10.1007/BF01745233.
4
Left ventricular performance in children: transthoracic versus transoesophageal measurement of M mode derived indices.儿童左心室功能:经胸与经食管测量M型衍生指标
Br Heart J. 1992 Nov;68(5):485-7. doi: 10.1136/hrt.68.11.485.