畸形矫正和肢体延长采用外控机动可延长髓内钉:两种不同钉子的比较。

Deformity correction and limb lengthening with externally controlled motorized extendable intramedullary nails: Comparison of 2 different nails.

机构信息

SBU Şişli Hamidiye Etfal Research and Training Hospital, Istanbul, Turkey.

出版信息

Acta Orthop Traumatol Turc. 2023 Jul;57(4):169-175. doi: 10.5152/j.aott.2023.23026.

Abstract

OBJECTIVE

The aim of this study was to assess and compare the clinical, radiological, and functional results of patients treated with FITBONE or PRECICE nails due to deformity and length discrepancy in their lower extremities.

METHODS

This retrospective cohort study included 41 patients with length discrepancy and deformity in their lower extremities, who underwent limb lengthening surgery with either FITBONE (group F) or PRECICE (group P) nails between 2010 and 2020. The mean postoperative follow-up period was 15.95 ± 4.75 months in group F (20 patients) and 20.48 ± 7.57 months in group P (21 patients). Lower extremity mechanical and anatomical axes were measured on x-rays preoperatively and at the end of treatment. Consolidation and distraction indexes were also calculated to assess bone healing. Lower Extremity Functional Scale test was used to evaluate functional outcomes and quality of life.

RESULTS

Neither of the treatment methods caused deviations in the mechanical axes and femoral distal angles (P > .05). No statistically significant difference in consolidation and distraction indexes was found between the groups (P > .05). Postoperative complications were seen in 3 of the patients in group F and 4 of the patients from group P. There was no significant difference in Lower Extremity Functional Scale scores between groups (P = .425).

CONCLUSION

This study has demonstrated that treatment with both the FITBONE and PRECICE nails resulted in improved physical and emotional functional outcomes. Both nails had similar radiographic results, complication rates, high patient compliance, and good cosmesis.

LEVEL OF EVIDENCE

Level III, Therapeutic Study.

摘要

目的

本研究旨在评估和比较因下肢畸形和长度差异而接受 FITBONE 或 PRECICE 钉治疗的患者的临床、影像学和功能结果。

方法

本回顾性队列研究纳入了 2010 年至 2020 年间因下肢畸形和长度差异接受肢体延长手术的 41 例患者,分别采用 FITBONE(F 组)或 PRECICE(P 组)钉治疗。F 组(20 例)和 P 组(21 例)的平均术后随访时间分别为 15.95 ± 4.75 个月和 20.48 ± 7.57 个月。术前和治疗结束时在 X 线片上测量下肢机械轴和解剖轴。还计算了骨愈合的巩固和分散指数。使用下肢功能量表(Lower Extremity Functional Scale,LEFS)测试评估功能结果和生活质量。

结果

两种治疗方法均未导致机械轴和股骨远端角度发生偏差(P >.05)。两组间巩固和分散指数无统计学差异(P >.05)。F 组 3 例患者和 P 组 4 例患者术后出现并发症。两组间 LEFS 评分无显著差异(P =.425)。

结论

本研究表明,使用 FITBONE 和 PRECICE 钉治疗均可改善生理和心理功能结果。两种钉的影像学结果、并发症发生率、患者依从性和美容效果相似。

证据水平

III 级,治疗性研究。