A critical comparison of radiocardiograms with 99mTc- and 131I-albumins was made to determine whether or not 99mTc-albumin can be used as a tracer for measuring blood volume (BV) and cardiac output (CO). Simultaneous injection of both isotopes was given to twenty-two patients to obtain radiocardiograms for each by means of a single scintillation counter with two pulse height analyzers. Such method allows for the determination of the energy levels for both 99mTc and 131I. The radiocardiographic pattern was somewhat different between 99mTc- and 131I-radiocardiograms: The ratio of left to right peak height was 16% on the average lower in the 99mTc-radiocardiogram in the 131I-one. The reason for the lower ratio is explained by greater absorption of 99mTc-radioactivity within the soft tissue interposing between the scintillation probe and heart. The values for 99mtc-derived blood volume were 7.4% on the average larger than those for 131I-derived blood volume (p less than 0.01), although the correlation was excellent (r = 0.98, p less than 0.01). There was no systemic difference between cardiac output determined by 99mTc- and 131I-albumins since the overstimation of blood volume can compensate for the understimation of CO/BV by 99mTc-study. In view of its rapid extravasation, 99mTc-albumin is not so appropriate tracer for accurate measurements of BV and CO/BV, although it may be used for measurement of cardiac output.
对使用99mTc-白蛋白和131I-白蛋白的放射心电图进行了严格比较,以确定99mTc-白蛋白是否可用作测量血容量(BV)和心输出量(CO)的示踪剂。同时向22名患者注射两种同位素,通过带有两个脉冲高度分析仪的单个闪烁计数器为每位患者获取放射心电图。这种方法可以确定99mTc和131I的能量水平。99mTc-放射心电图和131I-放射心电图之间的放射心电图模式略有不同:在99mTc-放射心电图中,左右峰值高度之比平均比131I-放射心电图低16%。该比值较低的原因是闪烁探头与心脏之间的软组织对99mTc放射性的吸收更强。99mTc衍生的血容量值平均比131I衍生的血容量值大7.4%(p<0.01),尽管相关性极佳(r=0.98,p<0.01)。99mTc-白蛋白和131I-白蛋白测定的心输出量没有系统性差异,因为血容量的高估可以弥补99mTc研究对CO/BV的低估。鉴于99mTc-白蛋白快速外渗,它不是准确测量BV和CO/BV的合适示踪剂,尽管它可用于测量心输出量。