• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

15-21-year results of the Charnley low-friction arthroplasty.

作者信息

Wroblewski B M

出版信息

Clin Orthop Relat Res. 1986 Oct(211):30-5.

PMID:3769266
Abstract

Ninety-three patients had had 116 Charnley low-friction arthroplasties (LFA) 15 to 21 years (mean, 16.6 years) previously. Their mean age at surgery was 53 years (range, 20-71 years). Fifty-two had osteoarthritis and 19 had rheumatoid arthritis. At follow-up, 85.3% were completely pain-free and 11.2% had occasional discomfort. Seventy-eight percent had near full or full range of movements. Acetabular bone-cement junction was unchanged in 32, and 20 had nonprogressive demarcation of the outer one third measuring less than 1 mm in width. In 36, socket demarcation was complete. Medial femoral cortex was unchanged in 56% and 44% showed loss of definition. Endosteal cavitation of the femur was present in 20.7%. Subsidence of the stem or the stem-cement complex was present in 29%. The diameter of the femoral cortex near the tip of the stem remained unaltered in 83.6%. The rate of socket wear was 0.096 mm/year, and there was a highly significant correlation between time and wear but no correlation between wear and patient's weight. Twenty-two and five-tenths percent of sockets migrated; this was statistically related to the depth of socket wear. The excellent clinical results of a relatively unsophisticated early surgical technique strongly supported the correct concept of the low-frictional torque. Improvements in the surgical technique and component design will further improve the long-term results.

摘要

相似文献

1
15-21-year results of the Charnley low-friction arthroplasty.
Clin Orthop Relat Res. 1986 Oct(211):30-5.
2
Charnley low-frictional torque arthroplasty in young rheumatoid and juvenile rheumatoid arthritis: 292 hips followed for an average of 15 years.年轻类风湿性关节炎和幼年类风湿性关节炎患者的Charnley低摩擦扭矩关节成形术:292例髋关节平均随访15年。
Acta Orthop. 2007 Apr;78(2):206-10. doi: 10.1080/17453670710013690.
3
Socket wear of Charnley low friction arthroplasty: fifteen year follow-up.查恩利低摩擦人工关节置换术的髋臼磨损:十五年随访
Bull Hosp Jt Dis. 1993;53(4):37-42.
4
Results of the Evora dual-mobility socket after a minimum follow-up of five years.埃沃拉双活动臼杯至少随访五年后的结果。
Rev Chir Orthop Reparatrice Appar Mot. 2008 Dec;94(8):e17-22. doi: 10.1016/j.rco.2007.10.015. Epub 2008 Jul 7.
5
Long-term follow-up of Charnley arthroplasty of the hip.髋关节Charnley人工关节置换术的长期随访
Clin Orthop Relat Res. 1979 Jun(141):28-43.
6
[Long-term review of homogeneous and consecutive series of 100 "Charnley"-type total hip prostheses].[对100例“查恩利”型全髋关节假体的同质连续系列进行长期回顾]
Rev Chir Orthop Reparatrice Appar Mot. 1996;82(4):306-12.
7
Charnley low-friction arthroplasty of the hip. Long-term results.查恩利髋关节低摩擦人工关节置换术。长期疗效
Clin Orthop Relat Res. 1993 Jul(292):191-201.
8
[Results of the Evora dual mobility socket: five years follow-up].[埃沃拉双动髋臼杯的结果:五年随访]
Rev Chir Orthop Reparatrice Appar Mot. 2008 Feb;94(1):37-42. doi: 10.1016/j.rco.2007.10.009. Epub 2008 Feb 1.
9
[Early aseptic loosening of the CF 30 femoral stem].[CF 30股骨柄早期无菌性松动]
Acta Chir Orthop Traumatol Cech. 2007 Feb;74(1):59-64.
10
[Survival of the cementless Bousquet dual mobility cup: Minimum 15-year follow-up of 437 total hip arthroplasties].[非骨水泥型布凯双动髋臼杯的生存率:437例全髋关节置换术至少15年的随访]
Rev Chir Orthop Reparatrice Appar Mot. 2008 Dec;94(8):731-9. doi: 10.1016/j.rco.2008.06.001. Epub 2008 Jul 24.

引用本文的文献

1
Long-term follow-up result of short metaphyseal femoral stem in primary total hip arthroplasty: A retrospective study.初次全髋关节置换术中短型股骨干骺端假体的长期随访结果:一项回顾性研究
World J Orthop. 2025 Jan 18;16(1):100173. doi: 10.5312/wjo.v16.i1.100173.
2
Dual mobility cups for total hip arthroplasty: tips and tricks.全髋关节置换术的双动髋臼杯:技巧与窍门
SICOT J. 2020;6:17. doi: 10.1051/sicotj/2020018. Epub 2020 Jun 17.
3
Hip arthroplasty for treatment of advanced osteonecrosis: comprehensive review of implant options, outcomes and complications.
髋关节置换术治疗晚期骨坏死:植入物选择、结果及并发症的综合综述
Orthop Res Rev. 2016 Jun 28;8:13-29. doi: 10.2147/ORR.S35547. eCollection 2016.
4
Long-term wear of dual mobility total hip replacement cups: explant study.双动全髋关节置换髋臼杯的长期磨损:取出研究
Int Orthop. 2018 Jan;42(1):41-47. doi: 10.1007/s00264-017-3525-z. Epub 2017 Jun 3.
5
Results of primary total hip replacement with first generation Bousquet dual mobility socket with more than twenty five years follow up. About a series of two hundred and twelve hips.使用第一代布凯双动髋臼杯进行初次全髋关节置换术超过25年的随访结果。涉及约212例髋关节。
Int Orthop. 2017 Mar;41(3):557-561. doi: 10.1007/s00264-016-3373-2. Epub 2016 Dec 26.
6
Low friction arthroplasty and dual mobility cup: a new gold standard.低摩擦关节成形术与双动髋臼杯:一种新的金标准。
Int Orthop. 2017 Mar;41(3):563-571. doi: 10.1007/s00264-016-3375-0. Epub 2016 Dec 20.
7
Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study.全髋关节置换术中双动轴承与标准轴承等效磨损性能的体外研究
Int Orthop. 2017 Mar;41(3):521-527. doi: 10.1007/s00264-016-3346-5. Epub 2016 Nov 22.
8
Bilaterally Primary Cementless Total Hip Arthroplasty for Severe Hip Ankylosis with Ankylosing Spondylitis.双侧初次非骨水泥型全髋关节置换术治疗强直性脊柱炎所致严重髋关节强直
Orthop Surg. 2016 Aug;8(3):352-9. doi: 10.1111/os.12254.
9
Biomechanical concept and clinical outcome of dual mobility cups.双动杯的生物力学概念和临床结果。
Int Orthop. 2012 Dec;36(12):2411-8. doi: 10.1007/s00264-012-1678-3. Epub 2012 Oct 17.
10
The dual mobility socket concept: experience with 668 cases.双动式 socket 理念:668 例经验。
Int Orthop. 2011 Feb;35(2):225-30. doi: 10.1007/s00264-010-1156-8. Epub 2010 Dec 24.