Miyaoka Ricardo, Azal Neto Wilmar, Pedro Renato Nardi
Division of Urology, Faculty of Medical Sciences, State University of Campinas - UNICAMP, Cidade Universitária Zeferino Vaz, Rua Vital Brasil, 80, CEP 13083-888, Campinas, SP, Brazil.
Clínica Urologia Campinas, Av. Francisco Glicério, 2331, salas 63/64, edifício Glicerio Office, Vl. Itapura, CEP 13020-210, Campinas, SP, Brazil.
Urol Case Rep. 2023 Aug 29;51:102549. doi: 10.1016/j.eucr.2023.102549. eCollection 2023 Nov.
Assessing ileal conduit for double J stents removal after radical cystectomy is not always a straightforward task as navigation inside the ileal loop can be challenging to manage due to the difficulty to maintain a waterfilled environment and its long and tortuous aspect.
We present a novel technique using a flexible ureteroscope that aims to ease this common demand with simple and readily available tools.
This technique has been successfully utilized in 2 patients now. No complications were documented.
We propose a novel surgical technique to improve endoscopic navigation in incontinent ileal loop urinary diversion.
在根治性膀胱切除术后评估回肠通道以取出双J支架并非总是一项简单的任务,因为由于难以维持充满水的环境以及回肠袢长且曲折的特点,在回肠袢内进行操作具有挑战性。
我们提出一种使用软性输尿管镜的新技术,旨在用简单且容易获得的工具满足这一常见需求。
该技术现已成功应用于2例患者。未记录到并发症。
我们提出一种新的手术技术,以改善在尿失禁性回肠袢尿液改道中的内镜操作。