Suppr超能文献

比较作为人类颅内活体模型的 Aachen 小型猪的动脉直径。

Comparison of artery diameters in the Aachen minipig serving as a human intracranial in vivo model.

机构信息

Department of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Germany.

出版信息

Lab Anim. 2024 Feb;58(1):65-72. doi: 10.1177/00236772231169809. Epub 2023 Sep 12.

Abstract

Minipigs are used as in vivo endovascular models, particularly in stroke and aneurysm research. However, detailed knowledge of the diameters of forelimb arteries that are commonly used as surrogates for human brain-supplying arteries are lacking. This study aimed to determine the diameters of forelimb and neck arteries in Aachen minipigs and to compare those to the diameters of human cerebral brain-supplying arteries in order to assess the validity of the Aachen minipig as a human intracranial in vivo model. We measured the diameters in the external carotid artery and eight different branches of the subclavian artery in 12 Aachen minipigs using angiographic imaging. Analysed arteries comprised the external carotid artery, axillary artery, brachial artery, subscapular artery first segment, subscapular artery second segment, external thoracic artery, caudal circumflex humeral artery, suprascapular artery and thoracodorsal artery. We compared these diameters to diameters of the following human brain-supplying arteries: terminal internal carotid artery (carotid-T and petrous segment), M1 segment of the middle cerebral artery, M2 segments of the middle cerebral artery, anterior cerebral artery, vertebral artery and basilar artery. Median diameters of porcine forelimb arteries ranged from 1.8 to 4.9 mm, and human brain supplying arteries ranged in diameter from 1.4 to 4.3 mm. Depending on the intended use, this allows porcine forelimb arteries to be selected which are statistically comparable to human brain-supplying vessels. In conclusion, we identified several equivalent arteries of the porcine subclavian branches that are comparable to human brain-supplying arteries. This may help to validate the minipig as a suitable in vivo model for neurovascular experiments.

摘要

小型猪被用作血管内的活体模型,特别是在中风和动脉瘤研究中。然而,常用作人脑供血动脉替代物的前肢动脉的直径的详细知识仍然缺乏。本研究旨在确定 Aachen 小型猪前肢和颈部动脉的直径,并将其与人脑供血动脉的直径进行比较,以评估 Aachen 小型猪作为人类颅内活体模型的有效性。我们使用血管造影成像技术测量了 12 只 Aachen 小型猪的颈外动脉和锁骨下动脉的 8 个不同分支的直径。分析的动脉包括颈外动脉、腋动脉、肱动脉、肩胛下动脉第一段、肩胛下动脉第二段、胸外动脉、旋肱后动脉、肩胛上动脉和胸背动脉。我们将这些直径与以下人脑供血动脉的直径进行了比较:终末颈内动脉(颈内动脉-T 和岩骨段)、大脑中动脉 M1 段、大脑中动脉 M2 段、大脑前动脉、椎动脉和基底动脉。猪前肢动脉的直径中位数范围为 1.8 至 4.9 毫米,人脑供血动脉的直径范围为 1.4 至 4.3 毫米。根据预期用途,可以选择与人类脑供血血管在统计学上可比的猪前肢动脉。总之,我们确定了一些与人类脑供血动脉相当的猪锁骨下分支的等效动脉。这可能有助于验证小型猪作为神经血管实验的合适活体模型。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验