In this paper, the details of the development and performance characterisation of a compact, low-power gamma spectrometer for environmental gamma radiation monitoring networks are presented. To reduce the power consumption and the size of the spectrometer, a gamma detector comprising a silicon photomultiplier coupled to a Gd3Ga3Al2O12:Ce,B (GGAG:Ce,B) scintillator has been used for gamma spectrometry. Initially, a Monte Carlo simulation study was carried out to verify the suitability of the 5 mm × 5 mm × 5 mm GGAG:Ce,B crystal for spectrometry of gamma sources in the energy range 60-1332 keV. For minimising the power consumption, the signal processing electronics has been custom designed. This electronics was realised using standard off-the-shelf components to reduce the cost. The developed spectrometer is of size 16 cm × 10 cm × 6 cm, weighs 600 g and consumes 600 mW power. The spectrometer is developed such that it could be directly interfaced with GSM/Xbee for wireless communication with the radiation monitoring networks. The lower-level discriminator threshold of the system is 40 keV and the total electronic noise is <20 keV. The experimentally measured sensitivity of the spectrometer for 137Cs (662 keV) is 2.4 cps/μGy/h at 3.5 V overvoltage. The spectrometer offers excellent linearity over the measured energy range of 60-1332 keV and an energy resolution of ~10% for 662 keV gamma-ray at room temperature.
本文介绍了一种用于环境伽马辐射监测网络的紧凑型、低功耗伽马谱仪的开发和性能特点。为了降低谱仪的功耗和尺寸,使用了一种由硅光电倍增管耦合到 Gd3Ga3Al2O12:Ce,B (GGAG:Ce,B) 闪烁体组成的伽马探测器进行伽马能谱测量。最初,进行了蒙特卡罗模拟研究,以验证 5mm×5mm×5mm GGAG:Ce,B 晶体在 60-1332keV 能量范围内用于伽马源光谱测量的适用性。为了最小化功耗,定制了信号处理电子设备。该电子设备使用标准现成组件实现,以降低成本。所开发的谱仪尺寸为 16cm×10cm×6cm,重量为 600g,功耗为 600mW。该谱仪的设计使其能够直接与 GSM/Xbee 接口,以便与辐射监测网络进行无线通信。系统的下限鉴别器阈值为 40keV,总电子噪声<20keV。在 3.5V 过电压下,对 137Cs(662keV)的谱仪实验测量灵敏度为 2.4cps/μGy/h。该谱仪在 60-1332keV 的测量能区具有优异的线性度,在室温下对 662keV 伽马射线的能量分辨率约为 10%。