Suppr超能文献

在活体猪模型中,经输尿管镜检查诱导的肾内压变化对肾血流的影响。

Change in renal blood flow in response to intrarenal pressure alterations induced by ureteroscopy in an in-vivo porcine model.

机构信息

Department of Urology, University of Michigan, 4432 Medical Science I, 1301 Catherine Street, Ann Arbor, MI, 48109-5330, USA.

Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.

出版信息

World J Urol. 2023 Nov;41(11):3181-3185. doi: 10.1007/s00345-023-04641-3. Epub 2023 Sep 30.

Abstract

INTRODUCTION

High irrigation rates are commonly used during ureteroscopy and can increase intrarenal pressure (IRP) substantially. Concerns have been raised that elevated IRP may diminish renal blood flow (RBF) and perfusion of the kidney. Our objective was to investigate the real-time changes in RBF while increasing IRP during Ureteroscopy (URS) in an in-vivo porcine model.

METHODS

Four renal units in two porcine subjects were used in this study, three experimental units and one control. For the experimental units, RBF was measured by placing an ultrasonic flow cuff around the renal artery, while performing ureteroscopy in the same kidney using a prototype ureteroscope with a pressure sensor at its tip. Irrigation was cycled between two rates to achieve targeted IRPs of 30 mmHg and 100 mmHg. A control data set was obtained by placing the ultrasonic flow cuff on the contralateral renal artery while performing ipsilateral URS.

RESULTS

At high IRP, RBF was reduced in all three experimental trials by 10-20% but not in the control trial. The percentage change in RBF due to alteration in IRP was internally consistent in each porcine renal unit and independent of slower systemic variation in RBF encountered in both the experimental and control units.

CONCLUSION

RBF decreased 10-20% when IRP was increased from 30 to 100 mmHg during ureteroscopy in an in-vivo porcine model. While this reduction in RBF is unlikely to have an appreciable effect on tissue oxygenation, it may impact heat-sink capacity in vulnerable regions of the kidney.

摘要

简介

在输尿管镜检查期间,通常会使用高灌溉率,这会大大增加肾内压(IRP)。人们担心升高的 IRP 可能会减少肾血流量(RBF)和肾脏的灌注。我们的目的是在活体猪模型中研究在输尿管镜检查(URS)期间增加 IRP 时 RBF 的实时变化。

方法

本研究使用了两个猪模型中的四个肾脏单位,三个实验单位和一个对照单位。对于实验单位,通过在肾动脉周围放置超声流量袖带来测量 RBF,同时在同一肾脏中使用带有尖端压力传感器的原型输尿管镜进行输尿管镜检查。通过在两个速率之间循环灌溉来实现目标 IRP 为 30mmHg 和 100mmHg。通过将超声流量袖带放置在对侧肾动脉上,同时在同侧进行 URS,获得对照数据集。

结果

在高 IRP 下,所有三个实验试验中的 RBF 均降低了 10-20%,但对照试验中没有降低。由于 IRP 改变引起的 RBF 百分比变化在每个猪肾单位中是一致的,并且独立于实验和对照单位中遇到的较慢的全身 RBF 变化。

结论

在活体猪模型中,当输尿管镜检查期间 IRP 从 30mmHg 增加到 100mmHg 时,RBF 降低了 10-20%。虽然这种 RBF 的减少不太可能对组织氧合产生明显影响,但它可能会影响肾脏脆弱区域的热阱能力。