局部晚期胰腺癌立体定向体部放射治疗中不同剂量计算算法的准确性分析

Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy.

作者信息

Song Yongchun, Yu Xuyao, Wang Yuwen, Dong Yang, Yuan Zhiyong

机构信息

Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, 300060, People's Republic of China.

Tianjin Medical University, Tianjin, 300070, People's Republic of China.

出版信息

J Cancer. 2023 Sep 4;14(14):2694-2699. doi: 10.7150/jca.87596. eCollection 2023.

Abstract

The dose distribution in different optimization algorithm plans of stereotactic radiotherapy (SBRT) for locally advanced pancreatic cancer (LAPC) were compared and analyzed using monte carlo dose calculate algorithm (MC). A retrospective study analyzed 26 LAPC patients treated with SBRT. The SBRT plans were designed by raytracing (RT) and fine size pencil beam (FSPB) algorithms in the CyberKnife (CK) precision system, all of which met the requirements of clinical target dose and organ at risk (OAR). Keeping the original optimization parameters unchanged, the RT and FSPB algorithm plans were recalculated by MC algorithm. The accuracy of different algorithm plnas were compared and analyzed by using planning parameters and dose distribution. There was no significant differences in the coverage and conformal index (CI) of the planned target volume (PTV) between RT and FSPB algorithm plans, but dose distribution of organ at risk (OAR) and the maximum dose outside the PTV boundary of 2 cm (D2cm) were lower in FSPB plans compared to RT plans, and this difference was statistically significant with p-values < 0.05. Compared to the MC algorithm, both RT algorithm and FSPB algorithm overestimated dose of the PTV and OAR. The RT algorithm was more consistent with the MC algorithm than the FSPB algorithm. The relative error of PTV coverage within the RT algorithm was 8.02% ± 1.53%, and the relative error range of OAR dose parameters was 3.32% -12.73%. Although the FSPB algorithm could achieve rapid dose drop-off around the PTV and lower dose distribution in the OAR for pancreatic cancer SBRT plans, the algorithm error were higher than the RT algorithm. RT and FSPB algorithm overestimated the dose in the target and OAR. That was important to evaluate the clinical plans.

摘要

使用蒙特卡罗剂量计算算法(MC)对局部晚期胰腺癌(LAPC)立体定向放射治疗(SBRT)不同优化算法计划中的剂量分布进行比较和分析。一项回顾性研究分析了26例接受SBRT治疗的LAPC患者。SBRT计划由射波刀(CK)精确系统中的射线追踪(RT)和精细尺寸笔形束(FSPB)算法设计,所有计划均满足临床靶区剂量和危及器官(OAR)的要求。在保持原始优化参数不变的情况下,通过MC算法对RT和FSPB算法计划进行重新计算。使用计划参数和剂量分布对不同算法计划的准确性进行比较和分析。RT和FSPB算法计划在计划靶体积(PTV)的覆盖度和适形指数(CI)方面无显著差异,但与RT计划相比,FSPB计划中危及器官(OAR)的剂量分布以及PTV边界外2 cm处的最大剂量(D2cm)较低,且这种差异具有统计学意义,p值<0.05。与MC算法相比,RT算法和FSPB算法均高估了PTV和OAR的剂量。RT算法比FSPB算法与MC算法更一致。RT算法中PTV覆盖度的相对误差为8.02%±1.53%,OAR剂量参数的相对误差范围为3.32%-12.73%。虽然FSPB算法在胰腺癌SBRT计划中可在PTV周围实现快速剂量下降并降低OAR中的剂量分布,但算法误差高于RT算法。RT和FSPB算法高估了靶区和OAR中的剂量。这对评估临床计划很重要。