扩展切割对齐评分工具(E-CAST)的同时效度。

Concurrent Validity of The Expanded Cutting Alignment Scoring Tool (E-CAST).

作者信息

Butler Lauren, Martinez Alexa, Erdman Ashley, Sugimoto Dai, Loewen Alex, Milian Eryn, Wyatt Charles, Hayden Kristin, DeVerna Amie, Tulchin-Francis Kirsten, Ulman Sophia

机构信息

Physical Therapy Florida International University.

Rehabilitation, Nicklaus Children's Hospital.

出版信息

Int J Sports Phys Ther. 2023 Oct 1;18(5):1147-1155. doi: 10.26603/001c.87633. eCollection 2023.

Abstract

BACKGROUND

The Expanded Cutting Alignment Scoring Tool (E-CAST) has been previously shown to be reliable when assessing lower extremity alignment during a 45-degree sidestep cut, however, the validity of this tool remains unknown. The purpose of this study was to assess the concurrent validity of the E-CAST by comparing visually identified movement errors from two-dimensional (2D) video with three-dimensional (3D) biomechanical variables collected using motion capture.

STUDY DESIGN

Cross Sectional.

METHODS

Sixty female athletes (age 14.1 ± 1.5 years) who regularly participated in cutting/pivoting sports performed a sidestep cut with 2D video and 3D motion capture simultaneously recording. One clinician scored the 2D videos for each limb using the E-CAST criteria. Joint angles and moments captured in 3D were computed for the trunk and knee. Receiver operating characteristic (ROC) curve analyses were performed to determine the accuracy of each E-CAST item and to provide cut-off points for risk factor identification.

RESULTS

ROC analyses identified a cut-off point for all biomechanical variables with sensitivity and specificity ranging from 70-85% and 55-89%, respectively. Across items, the area under the curve ranged from 0.67 to 0.91.

CONCLUSION

The E-CAST performed with acceptable to outstanding area under the curve values for all variables except static knee valgus.

LEVEL OF EVIDENCE

3b.

摘要

背景

先前研究表明,在评估45度侧步切入动作时下肢对线情况时,扩展式切入对线评分工具(E-CAST)具有可靠性,然而,该工具的有效性仍不明确。本研究的目的是通过比较二维(2D)视频中目视识别的动作错误与使用动作捕捉收集的三维(3D)生物力学变量,来评估E-CAST的同时效度。

研究设计

横断面研究。

方法

60名经常参加切入/旋转运动的女性运动员(年龄14.1±1.5岁)同时进行2D视频和3D动作捕捉的侧步切入动作。一名临床医生使用E-CAST标准对每个肢体的2D视频进行评分。计算躯干和膝盖在3D中捕捉到的关节角度和力矩。进行受试者工作特征(ROC)曲线分析,以确定每个E-CAST项目的准确性,并为危险因素识别提供切点。

结果

ROC分析确定了所有生物力学变量的切点,敏感性和特异性分别为70%-85%和55%-89%。在所有项目中,曲线下面积范围为0.67至0.91。

结论

除静态膝外翻外,E-CAST在所有变量的曲线下面积值方面表现为可接受至出色。

证据水平

3b。