Knee Surg Sports Traumatol Arthrosc. 2023 Nov;31(11):5137-5144. doi: 10.1007/s00167-023-07584-9. Epub 2023 Oct 5.
The aim of this prospective randomised controlled study was to compare wear characteristics and functional outcome between deep-dished mobile bearing (MB) and fixed bearing (FB) cemented total knee arthroplasty (TKA). We hypothesised that deep-dished MB reduces polyethylene wear and improves patient-reported outcome measures.
A total of 50 patients were randomised to receive a MB or FB tibia component of the same cemented TKA design. Patients were evaluated over a 5-year follow-up period. Medial and lateral wear were assessed using model-based Roentgen Stereophotogrammetric Analysis (RSA) and compared with the direct postoperative minimal joint space measurement. Functional outcome was assessed by the clinician-derived KSS and OKS, WOMAC, LEAS, and FJS-12. All data were derived using a general linear mixed model.
At 5-year follow-up, decreased wear in the MB compared to the FB group was observed on the lateral side (0.07 ± 0.17 mm, p = 0.026), but not on the medial side (0.31 ± 0.055 mm, p = 0.665). Functional outcomes improved with a statistical significant effect over time, with no significant differences between groups (all p > 0.17).
This model-based RSA study with 5-year follow-up showed that cemented deep-dished MB reduced lateral polyethylene wear as compared to FB in a single TKA system, whilst clinical outcomes were comparable. Longer follow-up is needed to establish clinical implications of these altered wear patterns and determine type of wear.
Level 1 randomised controlled trial.
本前瞻性随机对照研究的目的是比较深碟形活动衬垫(MB)和固定衬垫(FB)骨水泥固定膝关节置换术(TKA)的磨损特征和功能结果。我们假设深碟形 MB 可减少聚乙烯磨损并改善患者报告的结果测量。
共有 50 名患者被随机分配接受相同骨水泥 TKA 设计的 MB 或 FB 胫骨组件。患者在 5 年的随访期间接受评估。使用基于模型的放射立体摄影测量分析(RSA)评估内侧和外侧磨损,并与直接术后最小关节间隙测量进行比较。功能结果通过临床医生衍生的 KSS 和 OKS、WOMAC、LEAS 和 FJS-12 进行评估。所有数据均使用广义线性混合模型得出。
在 5 年的随访中,与 FB 组相比,MB 组在外侧观察到磨损减少(0.07±0.17mm,p=0.026),但在内侧未观察到磨损减少(0.31±0.055mm,p=0.665)。随着时间的推移,功能结果得到改善,且具有统计学显著效应,但组间无显著差异(所有 p>0.17)。
这项具有 5 年随访的基于模型的 RSA 研究表明,与 FB 相比,在单个 TKA 系统中,骨水泥深碟形 MB 可减少外侧聚乙烯磨损,而临床结果相当。需要更长时间的随访来确定这些改变的磨损模式的临床意义并确定磨损类型。
1 级随机对照试验。