A kidney with triple renal arteries was removed from an HLA identical donor and transplanted to her brother using the donor hypogastric artery as an autogenous graft. The kidney was preserved by hypothermic, hyperkalemic, hyperosmolar washout solution while the three separate renal artery-hypogastric artery autograft anastomoses were being performed in an ex vivo position. Subsequently, the end to side autogenous hypogastric artery patch graft to external iliac artery anastomosis was completed. Prompt renal function occurred and after 18 months the serum creatinine level remained unchanged.

摘要

从一位 HLA 配型相同的供体身上取出一个具有三条肾动脉的肾脏,并将供体的髂内动脉作为自体移植物移植给她的兄弟。在体外进行三条独立的肾动脉 - 髂内动脉自体移植吻合时,肾脏用低温、高钾、高渗冲洗液保存。随后,完成了自体髂内动脉补片移植与髂外动脉的端侧吻合。肾功能迅速恢复,18 个月后血清肌酐水平保持不变。