• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Tibial component fixation in knee arthroplasty.

作者信息

Ryd L, Lindstrand A, Rosenquist R, Selvik G

出版信息

Clin Orthop Relat Res. 1986 Dec(213):141-9.

PMID:3780083
Abstract

Using roentgen stereophotogrammetric analysis (RSA), the integrity of the bond between the tibial component and the tibia was studied in seven knees, implanted with a cemented Kinematic total knee prosthesis for gonarthrosis. Migration ranging from 0.3 to 1.9 mm over a two-year period occurred in all seven cases. Displacement, induced by external forces, ranging from 0.2 to 1.0 mm was observed in five cases. Measurable migration and inducible displacement may be the rule rather than an exception in total knee arthroplasty (TKA). Accordingly, absolute rigid fixation would not be necessary for successful function of a TKA.

摘要

相似文献

1
Tibial component fixation in knee arthroplasty.
Clin Orthop Relat Res. 1986 Dec(213):141-9.
2
Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation.膝关节置换术中的微动。胫骨假体固定的X线立体摄影测量分析。
Acta Orthop Scand Suppl. 1986;220:1-80.
3
Micromotion of noncemented Freeman-Samuelson knee prostheses in gonarthrosis. A roentgen-stereophotogrammetric analysis of eight successful cases.非骨水泥型Freeman-Samuelson膝关节假体在膝关节病中的微动。8例成功病例的X线立体摄影测量分析。
Clin Orthop Relat Res. 1988 Apr(229):205-12.
4
Micromotion of conventionally cemented all-polyethylene tibial components in total knee replacements. A roentgen stereophotogrammetric analysis of migration and inducible displacement.全膝关节置换术中传统骨水泥固定的全聚乙烯胫骨部件的微动。迁移和诱导位移的X线立体摄影测量分析。
Arch Orthop Trauma Surg (1978). 1987;106(2):82-8. doi: 10.1007/BF00435419.
5
The influence of metal backing in unicompartmental tibial component fixation. An in vivo roentgen stereophotogrammetric analysis of micromotion.金属衬背在单髁胫骨部件固定中的影响。微动的体内X线立体摄影测量分析。
Arch Orthop Trauma Surg. 1992;111(3):148-54. doi: 10.1007/BF00388089.
6
Early postoperative fixation of tibial components: an in vivo roentgen stereophotogrammetric analysis.胫骨部件的早期术后固定:一项体内X线立体摄影测量分析
J Orthop Res. 1993 Jan;11(1):142-8. doi: 10.1002/jor.1100110116.
7
The effect of a stem on the tibial component of knee arthroplasty. A roentgen stereophotogrammetric study of uncemented tibial components in the Freeman-Samuelson knee arthroplasty.
J Bone Joint Surg Br. 1990 Mar;72(2):252-8. doi: 10.1302/0301-620X.72B2.2312565.
8
Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint.
Clin Orthop Relat Res. 1992 Mar(276):56-65.
9
Micromotion between the half bearings in the interax prosthesis: a roentgen stereophotogrammetric analysis.Interax假体中半轴承之间的微动:一项X线立体摄影测量分析
J Arthroplasty. 2001 Dec;16(8):991-7. doi: 10.1054/arth.2001.25560.
10
Migration of the tibial component in successful unicompartmental knee arthroplasty. A clinical, radiographic and roentgen stereophotogrammetric study.成功的单髁膝关节置换术中胫骨假体的移位。一项临床、影像学和X线立体摄影测量研究。
Acta Orthop Scand. 1983 Jun;54(3):408-16. doi: 10.3109/17453678308996593.

引用本文的文献

1
Randomized controlled trial comparing traditional versus enhanced-fixation designs of a novel cemented total knee arthroplasty tibial component.一项随机对照试验,比较新型骨水泥型全膝关节置换胫骨部件的传统固定设计与增强固定设计。
Bone Jt Open. 2024 Jan 17;5(1):20-27. doi: 10.1302/2633-1462.51.BJO-2023-0121.
2
RSA migration of total knee replacements.全膝关节置换的 RSA 迁移。
Acta Orthop. 2018 Jun;89(3):320-328. doi: 10.1080/17453674.2018.1443635. Epub 2018 Mar 6.
3
Prospective randomised clinical trial assessing subsidence and rotation, using radiostereometric analysis, of two modular cementless femoral stems (Global K2 and Apex).
一项前瞻性随机临床试验,采用放射立体测量分析评估两种模块化非骨水泥股骨柄(Global K2和Apex)的下沉和旋转情况。
J Orthop. 2014 Apr 22;11(2):96-102. doi: 10.1016/j.jor.2014.02.001. eCollection 2014 Jun.
4
Does a new knee design perform as well as the design it replaces?新型膝关节设计的表现是否与所替代的设计一样好?
Bone Joint Res. 2012 Dec 1;1(12):315-23. doi: 10.1302/2046-3758.112.2000064. Print 2012 Dec.
5
Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.胫骨组件的早期迁移与晚期翻修有关:21000 例膝关节置换术的系统评价和荟萃分析。
Acta Orthop. 2012 Dec;83(6):614-24. doi: 10.3109/17453674.2012.747052. Epub 2012 Nov 9.
6
Longitudinal migration and inducible displacement of the Mobility Total Ankle System.Mobility Total 踝关节系统的纵向迁移和诱导位移。
Acta Orthop. 2012 Aug;83(4):394-400. doi: 10.3109/17453674.2012.712890. Epub 2012 Aug 10.
7
Fixation of the tibial component in knee arthroplasty after six weeks.
Int Orthop. 1995;19(2):89-93. doi: 10.1007/BF00179967.
8
The influence of metal backing in unicompartmental tibial component fixation. An in vivo roentgen stereophotogrammetric analysis of micromotion.金属衬背在单髁胫骨部件固定中的影响。微动的体内X线立体摄影测量分析。
Arch Orthop Trauma Surg. 1992;111(3):148-54. doi: 10.1007/BF00388089.