Suppr超能文献

负重全髋关节置换模型中多孔涂层的对比研究。

A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model.

作者信息

Turner T M, Sumner D R, Urban R M, Rivero D P, Galante J O

出版信息

J Bone Joint Surg Am. 1986 Dec;68(9):1396-409.

PMID:3782212
Abstract

The purposes of this study were to compare ingrowth of bone into three types of porous coating and to determine the effect of the type of porous coating and the degree of coverage of the stem on the remodeling of bone on the femoral side in cementless hip arthroplasty. A left total hip arthroplasty was performed in forty dogs. Thirty of the dogs had a titanium-alloy femoral prosthesis that had had one of three types of commercially pure titanium porous material applied along the length of the anterior and posterior surfaces of the stem: ten with sintered fiber-metal, ten with sintered beads, and ten with plasma flame-spray coating. The remaining ten dogs had a femoral component that was circumferentially coated with commercially pure titanium that was plasma flame-sprayed along the length of the stem. In each group, five animals were killed at one month and five were killed at six months. Ingrowth of bone into all three types of porous coating was observed, indicating secure fixation of all components. By six months, there was more ingrowth of bone and new medullary bone adjacent to the proximal and distal aspects of the stems compared with the middle level of the stems in all groups. No significant difference in ingrowth of bone was observed in the beaded surface (25.2 per cent) and the fiber-metal surface (16.6 per cent) at one month, but at six months there was significantly less ingrowth into the beaded surface (23.3 per cent) than into the fiber-metal surface (37.3 per cent). In all groups, a proximal-to-distal gradient of loss of cortical bone was observed by six months. The group of dogs that had the stem with the circumferential coating experienced more severe loss of bone than did the three groups that had a stem with a partial coating. The magnitude of loss of bone was dependent on the extent rather than the type of porous coating.

摘要

本研究的目的是比较骨长入三种类型多孔涂层的情况,并确定多孔涂层类型和柄的覆盖程度对非骨水泥型髋关节置换术中股骨侧骨重塑的影响。对40只犬进行了左侧全髋关节置换术。其中30只犬植入了钛合金股骨假体,该假体的柄的前后表面沿长度方向应用了三种商业纯钛多孔材料中的一种:10只采用烧结纤维金属,10只采用烧结珠粒,10只采用等离子火焰喷涂涂层。其余10只犬植入的股骨部件在柄的长度方向上沿圆周方向涂覆有等离子火焰喷涂的商业纯钛。每组中,5只动物在1个月时处死,5只在6个月时处死。观察到骨长入所有三种类型的多孔涂层,表明所有部件固定牢固。到6个月时,与所有组柄的中部相比,柄的近端和远端附近有更多的骨长入和新的髓质骨。1个月时,在珠粒表面(25.2%)和纤维金属表面(16.6%)观察到的骨长入无显著差异,但在6个月时,珠粒表面(23.3%)的骨长入明显少于纤维金属表面(37.3%)。到6个月时,所有组均观察到皮质骨丢失的近端至远端梯度。柄采用圆周涂层的犬组比柄采用部分涂层的三组经历了更严重的骨丢失。骨丢失的程度取决于多孔涂层的范围而非类型。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验