Suppr超能文献

全髋关节假体的机械松动。一项影像学和X线立体摄影测量研究。

Mechanical loosening of total hip prostheses. A radiographic and roentgen stereophotogrammetric study.

作者信息

Mjöberg B, Selvik G, Hansson L I, Rosenqvist R, Onnerfält R

出版信息

J Bone Joint Surg Br. 1986 Nov;68(5):770-4. doi: 10.1302/0301-620X.68B5.3782242.

Abstract

Twenty patients were examined by standard radiography and roentgen stereophotogrammetric analysis (RSA) during a two-year period after total hip arthroplasty. Eleven of the acetabular components migrated cranially and three femoral components migrated distally. This migration was most rapid during the first four months after operation. Our findings support the possibility that mechanical loosening is initiated by thermal injury during polymerisation of the cement; the less frequent migration of the metallic femoral component compared with the polyethylene acetabular component may be because the metal acts as a heat sink. Standard radiographs were inadequate for assessment of early mechanical loosening, whereas RSA could reveal migration within four months of the arthroplasty.

摘要

在全髋关节置换术后两年内,对20例患者进行了标准X线摄影和X线立体摄影测量分析(RSA)。11个髋臼组件向头侧移位,3个股骨组件向远侧移位。这种移位在术后的前四个月最为迅速。我们的研究结果支持以下可能性,即骨水泥聚合过程中的热损伤引发了机械性松动;与聚乙烯髋臼组件相比,金属股骨组件移位较少见可能是因为金属起到了散热器的作用。标准X线片不足以评估早期机械性松动,而RSA能够在关节置换术后四个月内发现移位情况。