合成磁共振成像联合快速自旋回波-螺旋桨扩散加权成像用于鉴别头颈部良恶性肿瘤的初步研究

Synthetic MRI plus FSE-PROPELLER DWI for differentiating malignant from benign head and neck tumors: a preliminary study.

作者信息

Wen Baohong, Zhang Zanxia, Zhu Jing, Liu Liang, Liu Zijun, Ma Xiaoyue, Wang Kaiyu, Xie Lizhi, Zhang Yong, Cheng Jingliang

机构信息

Department of MRI, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.

MR Research China, GE Healthcare, Beijing, China.

出版信息

Front Oncol. 2023 Sep 27;13:1225420. doi: 10.3389/fonc.2023.1225420. eCollection 2023.

Abstract

BACKGROUND

Preoperative classification of head and neck (HN) tumors remains challenging, especially distinguishing early cancerogenic masses from benign lesions. Synthetic MRI offers a new way for quantitative analysis of tumors. The present study investigated the application of synthetic MRI and stimulus and fast spin echo diffusion-weighted imaging with periodically rotated overlapping parallel lines with enhanced reconstruction (FSE-PROPELLER DWI) to differentiate malignant from benign HN tumors.

MATERIALS AND METHODS

Forty-eight patients with pathologically confirmed HN tumors were retrospectively recruited between August 2022 and October 2022. The patients were divided into malignant (n = 28) and benign (n = 20) groups. All patients were scanned using synthetic MRI and FSE-PROPELLER DWI. T1, T2, and proton density (PD) values were acquired on the synthetic MRI and ADC values on the FSE-PROPELLER DWI.

RESULTS

Benign tumors (ADC: 2.03 ± 0.31 × 10 mm/s, T1: 1741.13 ± 662.64 ms, T2: 157.43 ± 72.23 ms) showed higher ADC, T1, and T2 values compared to malignant tumors (ADC: 1.46 ± 0.37 × 10 mm/s, T1: 1390.06 ± 241.09 ms, T2: 97.64 ± 14.91 ms) (all P<0.05), while no differences were seen for PD values. ROC analysis showed that T2+ADC (cut-off value, > 0.55; AUC, 0.950) had optimal diagnostic performance vs. T1 (cut-off value, ≤ 1675.84 ms; AUC, 0.698), T2 (cut-off value, ≤ 113.24 ms; AUC, 0.855) and PD (cut off value, > 80.67 pu; AUC, 0.568) alone in differentiating malignant from benign lesions (all P<0.05); yet, the difference in AUC between ADC and T2+ADC or T2 did not reach statistical significance.

CONCLUSION

Synthetic MRI and FSE-PROPELLER DWI can quantitatively differentiate malignant from benign HN tumors. T2 value is comparable to ADC value, and T2+ADC values could improve diagnostic efficacy., apparent diffusion coeffificient, head and neck tumors.

摘要

背景

头颈部(HN)肿瘤的术前分类仍然具有挑战性,尤其是区分早期致癌肿块与良性病变。合成磁共振成像(MRI)为肿瘤的定量分析提供了一种新方法。本研究探讨了合成MRI以及刺激与快速自旋回波扩散加权成像结合周期性旋转重叠平行线增强重建技术(FSE-PROPELLER DWI)在鉴别头颈部恶性肿瘤与良性肿瘤中的应用。

材料与方法

回顾性纳入2022年8月至2022年10月间48例经病理证实的头颈部肿瘤患者。将患者分为恶性组(n = 28)和良性组(n = 20)。所有患者均接受合成MRI和FSE-PROPELLER DWI扫描。在合成MRI上获取T1、T2和质子密度(PD)值,在FSE-PROPELLER DWI上获取表观扩散系数(ADC)值。

结果

与恶性肿瘤(ADC:1.46±0.37×10⁻³mm²/s,T1:1390.06±241.09 ms,T2:97.64±14.91 ms)相比,良性肿瘤(ADC:2.03±0.31×10⁻³mm²/s,T1:1741.13±662.64 ms,T2:157.43±72.23 ms)的ADC、T1和T2值更高(均P<0.05),而PD值无差异。ROC分析显示,在鉴别恶性与良性病变方面,T2+ADC(截断值>0.55;曲线下面积[AUC],0.950)的诊断性能优于单独的T1(截断值≤1675.84 ms;AUC,0.698)、T2(截断值≤113.24 ms;AUC,0.855)和PD(截断值>80.67 pu;AUC,0.568)(均P<0.05);然而,ADC与T2+ADC或T2之间的AUC差异未达到统计学意义。

结论

合成MRI和FSE-PROPELLER DWI能够对头颈部恶性肿瘤与良性肿瘤进行定量鉴别。T2值与ADC值相当,T2+ADC值可提高诊断效能。 表观扩散系数,头颈部肿瘤。