A method for determining tobacco-specific nitrosamines (TSNAs) in tobacco and cigarette smoke using liquid chromatography-tandem mass spectrometry was established. The established method amended the deficiencies that exist in current mainstream methods. In this method, TSNAs in tobacco and cigarette smoke were extracted by water. The aqueous extract was then extracted by dichloromethane, and the extract could be analyzed by liquid chromatography-tandem mass spectrometry after a solvent replacement. This method was used to analyze flue-cured tobacco samples, and the response of the target compounds was about 10 times higher than that of the ammonium acetate extraction method. When analyzing cigarette smoke samples, the response strength and chromatographic peak purity of the target compounds were also significantly improved. The proposed method exhibited good linearities for both tobacco and cigarette smoke samples (r > 0.99). The limits of detection (LODs) for tobacco and cigarette smoke samples were 0.2-1.0 ng/g and 0.1-0.3 ng/cigarette, respectively. Additionally, this method exhibited desirable accuracy and precision. The TSNAs recovery values from tobacco and cigarette smoke samples ranged from 95.7 % to 107.7 % with inter- and intra-day relative standard deviations (RSDs) of less than 7.4 %. This method is simple, effective, and has wide adaptability. It is a useful upgrade to the existing methods for analyzing TSNAs in tobacco and cigarette smoke.
建立了一种使用液相色谱-串联质谱法测定烟草及卷烟烟气中烟草特有亚硝胺(TSNAs)的方法。所建立的方法修正了当前主流方法中存在的缺陷。在该方法中,烟草及卷烟烟气中的TSNAs用水进行萃取。水相萃取液再用二氯甲烷萃取,萃取液经溶剂置换后可通过液相色谱-串联质谱法进行分析。该方法用于分析烤烟样品时,目标化合物的响应比醋酸铵萃取法高约10倍。在分析卷烟烟气样品时,目标化合物的响应强度和色谱峰纯度也显著提高。所提出的方法对烟草和卷烟烟气样品均表现出良好的线性关系(r>0.99)。烟草和卷烟烟气样品的检测限分别为0.2 - 1.0 ng/g和0.1 - 0.3 ng/支。此外,该方法具有良好的准确度和精密度。烟草和卷烟烟气样品中TSNAs的回收率在95.7%至107.7%之间,日内和日间相对标准偏差(RSDs)均小于7.4%。该方法简单、有效且具有广泛的适应性。它是对现有烟草及卷烟烟气中TSNAs分析方法的一次有益升级。