Suppr超能文献

不同预成型锉在成形能力评估方面的比较:一项显微 CT 研究。

Evaluation of shaping ability of different glide path instruments: a micro-computed tomography study.

机构信息

Department of Endodontics, School of Dentistry, Dicle University, Diyarbakır, Turkey.

Department of Endodontics, School of Dentistry, İstanbul Health and Technology University, İstanbul, Turkey.

出版信息

BMC Oral Health. 2023 Oct 24;23(1):780. doi: 10.1186/s12903-023-03529-3.

Abstract

BACKGROUND

This study aimed to compare the shaping ability of different instruments, TruNatomy Glider (TRN-G), WaveOne Gold Glider (WOG-G), and ProGlider (Pro-G) using micro-computed tomography (micro-CT).

METHODS

The mesial canals of 27 mandibular molars with two separate mesial canals and moderate curvature were included in this study [n = 27 mesiobuccal (MB) and mesiolingual (ML) root canal]. According to the manufacturer's instructions, the glide path was created with TRN-G, WOG-G, and Pro-G glide path instruments (n = 9 MB and ML root canal in each group). Micro-CT scanning was performed before and after preparation. Mesiodistal (MD) and buccolingual (BL) transportation and the centering ratio were measured at three levels within the canal (3, 5 and 7 mm). A three-way robust ANOVA was used to compare the parameters.

RESULTS

TRN-G showed significantly greater transportation in the MD direction than the other instruments throughout the root canal (overall root canal) (p < 0.05). The best centering ability in the BL direction was shown by the WOG-G, regardless of level within the canal and canal distinction (MB vs. ML) (p < 0.05). There was no significant difference between groups according to the level within the canal and canal parameters (p > 0.05). Whether the root canal was MB or ML did not affect centering or transportation (p > 0.05).

CONCLUSIONS

Glide path instruments can be used to shape moderately curved canals with minimal apical transportation and better centering ability. All three tested glide path files can used safely before the shaping file.

摘要

背景

本研究旨在通过 micro-CT 比较不同器械(TruNatomy Glider(TRN-G)、WaveOne Gold Glider(WOG-G)和 ProGlider(Pro-G))的成形能力。

方法

本研究纳入了 27 颗具有两个独立近中管且中度弯曲的下颌磨牙,近中管[ n = 27 个近颊(MB)和近舌(ML)根管]。根据制造商的说明,使用 TRN-G、WOG-G 和 Pro-G 导丝预备器(每组 n = 9 个 MB 和 ML 根管)制备根管的初始形态。预备前后进行 micro-CT 扫描。在根管内三个水平(3、5 和 7 mm)测量近远中向(MD)和颊舌向(BL)的偏移量和中心率。采用三因素稳健方差分析比较参数。

结果

TRN-G 在整个根管(整体根管)的 MD 方向上显示出比其他器械更大的偏移量( p < 0.05)。在 BL 方向上,WOG-G 显示出最佳的中心定位能力,而与根管内的水平和根管区分(MB 与 ML)无关( p < 0.05)。根据根管内的水平和根管参数,各组之间没有显著差异( p > 0.05)。根管是 MB 还是 ML 并不影响中心定位或偏移量( p > 0.05)。

结论

导丝预备器可用于成形中度弯曲的根管,以实现最小的根尖偏移和更好的中心定位能力。在成形锉之前,所有三种测试的导丝预备器都可以安全使用。