Suppr超能文献

加热对硅酸三钙根管封闭剂理化性能的影响。

The effects of heating on the physicochemical properties of tricalcium silicate root canal sealers.

机构信息

Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.

Department of Diagnosis & Oral Health, Division of Endodontics, University of Louisville, Louisville, KY, USA.

出版信息

Braz Dent J. 2023 Jul-Aug;34(4):34-43. doi: 10.1590/0103-6440202305237.

Abstract

This study evaluated the effect of heating on the physicochemical properties and surface changes of tricalcium silicate sealers. Three tricalcium silicate root canal sealers (Bio-C Sealer, BioRoot-RCS, EndoSequence BC Sealer), and one epoxy resin-based sealer (AH Plus; control) were tested. The effect of heating on setting time (ST) and flowability were assessed according to ANSI/ADA 57 and ISO 6876 standards. Solubility and dimensional change (DC) of the set sealers were evaluated at 24 hours and after 30 days; the pH of the water used in the DC testing was also measured. Tests were repeated with heated sealers in an oven at 100 °C for 1 min. SEM and EDS analysis were performed. Data were analyzed using One-Way ANOVA and Tukey post-hoc tests (α=5%). Heating decreased the ST for AH Plus and EndoSequence (p<0.05). Heating reduced flowability (p<0.05) and increased pH for AH Plus (p<0.05). The solubility of Bio-C (dried specimens) was not in accordance with the ANSI/ADA standard. The solubility of EndoSequence was significantly higher (p<0.05) when it was heated and dried after 30 days. DC of Bio-C (24 h and 30 days), BioRoot-RCS (30 days) and AH Plus (24 h and 30 days) were not in accordance with the standards. SEM and EDS analysis showed significant changes in sealer microstructure after heating. In conclusion, heating decreased the ST and increased the solubility of EndoSequence BC sealer. No significant changes in flowability, DC, and pH were identified for all three tricalcium silicate sealers after heat application. However, all sealers had significant surface changes.

摘要

本研究评估了加热对三钙矽酸盐封固剂理化性质和表面变化的影响。测试了三种三钙矽酸盐根管封固剂(Bio-C Sealer、BioRoot-RCS、EndoSequence BC Sealer)和一种环氧树脂基封固剂(AH Plus;对照组)。根据 ANSI/ADA 57 和 ISO 6876 标准,评估加热对凝固时间(ST)和流动性的影响。在 24 小时和 30 天后评估凝固封固剂的溶解度和尺寸变化(DC);还测量了 DC 测试中使用的水的 pH 值。在 100°C 的烤箱中加热封固剂 1 分钟后,重复测试。进行 SEM 和 EDS 分析。使用单因素方差分析和 Tukey 事后检验(α=5%)对数据进行分析。加热降低了 AH Plus 和 EndoSequence 的 ST(p<0.05)。加热降低了流动性(p<0.05)并增加了 AH Plus 的 pH 值(p<0.05)。Bio-C(干燥样本)的溶解度不符合 ANSI/ADA 标准。加热并在 30 天后干燥后,EndoSequence 的溶解度显著升高(p<0.05)。Bio-C(24 小时和 30 天)、BioRoot-RCS(30 天)和 AH Plus(24 小时和 30 天)的 DC 不符合标准。SEM 和 EDS 分析显示加热后封固剂微观结构发生显著变化。结论是,加热降低了 EndoSequence BC 封固剂的 ST 并增加了其溶解度。加热后,三种三钙矽酸盐封固剂的流动性、DC 和 pH 值均无显著变化。然而,所有封固剂的表面均发生显著变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/65f2/10642270/047aa2b24ee9/1806-4760-bdj-34-04-34-gch1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验