一项评估和比较使用计算机辅助设计/计算机辅助制造制作的三维导板放置的种植体的角度、线性和深度偏差以及骨密度差异与使用骨笔套件放置的种植体在上颌和下颌牙槽嵴中的研究。

An study to assess and compare the angular, linear, and depth deviation as well as the difference in bone density of implants placed using computer-aided design/computer-aided manufacturing fabricated three-dimensional guides versus the implants placed using bone pen kit in maxillary and mandibular ridges.

机构信息

Department of Prosthodontics and Crown and Bridge, Subharti Dental College, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.

Department of Oral and Maxillofacial Surgery, Subharti Dental College, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.

出版信息

J Indian Prosthodont Soc. 2023 Jul-Sep;23(3):266-276. doi: 10.4103/jips.jips_193_23.

Abstract

AIM

The aim is to assess and compare angular, linear, and depth deviation and difference in bone density of dental implants placed using computer aided design/computer aided manufacturing (CAD/CAM) fabricated surgical guides versus implants placed using Bone Pen Kit. Till now, no original research exists in the search engines such as Pubmed, Google Scholar, Science Direct, and Research Gate on this kit.

SETTINGS AND DESIGN

In vivo- Randomised control trial.

MATERIALS AND METHODS

Twenty clinical cases were selected and split into two distinct groups. Group 1 involved the placement of 10 implants using CAD/CAM fabricated three dimensional guides and Group 2 involved the placement of 10 implants using Bone Pen Kit. Four deviation parameters were evaluated, which included: (a) Angular deviation, (b) Linear deviation at implant platform, (c) Linear deviation at implant apex, and (d) Depth deviation and difference in bone density before and after implant placement was also evaluated.

STATISTICAL ANALYSIS USED

SPSS software version 23 was utilized for the analysis of the data. The comparison was made using the Whitney test, and Wilcoxon signed rank test.

RESULTS

When comparing angular deviation, the results indicated a statistically significant difference with a P < 0.05. The values observed for angular and linear deviation in Group 2 were significantly greater than those in Group 1. No statistically significant difference in depth and linear deviation was found at the implant platform among the two groups. Bone density before and after implant placement was significantly higher in Group 1.

CONCLUSIONS

(1) Angular and linear deviation at the apex in Group 2 exhibited higher values in comparison to Group 1, (2) No difference in depth and linear deviation at the implant platform was found among the two groups, and (3) There was no difference in change in bone density among two groups.

摘要

目的

评估和比较使用计算机辅助设计/计算机辅助制造(CAD/CAM)制作的外科导板放置的种植体的角度、线性和深度偏差以及骨密度差异,与使用 Bone Pen Kit 放置的种植体进行比较。到目前为止,在 Pubmed、Google Scholar、Science Direct 和 Research Gate 等搜索引擎中,尚未有关于该套件的原始研究。

设置和设计

体内-随机对照试验。

材料和方法

选择了 20 个临床病例,并将其分为两组。第 1 组涉及使用 CAD/CAM 制作的三维导板放置 10 个种植体,第 2 组涉及使用 Bone Pen Kit 放置 10 个种植体。评估了四个偏差参数,包括:(a)角度偏差,(b)种植体平台处的线性偏差,(c)种植体尖端处的线性偏差,(d)种植前后骨密度的深度偏差和差异。

使用的统计分析

使用 SPSS 软件版本 23 对数据进行分析。使用 Whitney 检验和 Wilcoxon 符号秩检验进行比较。

结果

当比较角度偏差时,结果表明具有统计学意义的差异,P < 0.05。第 2 组的角度和线性偏差值明显大于第 1 组。两组间种植体平台处深度和线性偏差无统计学差异。第 1 组种植前后骨密度明显较高。

结论

(1)与第 1 组相比,第 2 组的根尖角度和线性偏差值较高,(2)两组间种植体平台处深度和线性偏差无差异,(3)两组间骨密度变化无差异。