Suppr超能文献

健康志愿者定量 4D 流 MRI 衍生的 2D 流 MRI 参数的胸主动脉正常值。

Quantitative 4D flow MRI-derived thoracic aortic normal values of 2D flow MRI parameters in healthy volunteers.

机构信息

Diagnostic and Interventional Radiology, Leipzig University, Leipzig, Germany.

Diagnostic and Interventional Radiology, Leipzig Heart Centre University Hospital, Leipzig, Germany.

出版信息

Rofo. 2024 Mar;196(3):273-282. doi: 10.1055/a-2175-4165. Epub 2023 Nov 9.

Abstract

PURPOSE

To utilize 4 D flow MRI to acquire normal values of "conventional 2 D flow MRI parameters" in healthy volunteers in order to replace multiple single 2 D flow measurements with a single 4 D flow acquisition.

MATERIALS AND METHODS

A kt-GRAPPA accelerated 4 D flow sequence was used. Flow volumes were assessed by forward (FFV), backward (BFV), and net flow volumes (NFV) [ml/heartbeat] and flow velocities by axial (VAX) and absolute velocity (VABS) [m/s] in 116 volunteers (58 females, 43 ± 13 years). The aortic regurgitant fraction (RF) was calculated.

RESULTS

The sex-neutral mean FFV, BFV, NFV, and RF in the ascending aorta were 93.5 ± 14.8, 3.6 ± 2.8, 89.9 ± 0.6 ml/heartbeat, and 3.9 ± 2.9 %, respectively. Significantly higher values were seen in males regarding FFV, BFV, NFV and RF, but there was no sex dependency regarding VAX and VABS. The mean maximum VAX was lower (1.01 ± 0.31 m/s) than VABS (1.23 ± 0.35 m/s). We were able to determine normal ranges for all intended parameters.

CONCLUSION

This study provides quantitative 4 D flow-derived thoracic aortic normal values of 2 D flow parameters in healthy volunteers. FFV, BFV, NFV, and VAX did not differ significantly from single 2 D flow acquisitions and could therefore replace time-consuming multiple single 2 D flow acquisitions. VABS should not be used interchangeably.

KEY POINTS

· 4 D flow MRI can be used to replace 2 D flow MRI measurements.. · The parameter absolute velocities can be assessed by 4 D flow MRI.. · There are sex-dependent differences regarding forward, backward, net aortic blood flow and the aortic valve regurgitant fraction..

摘要

目的

利用 4D 流 MRI 获取健康志愿者“传统 2D 流 MRI 参数”的正常值,以便用单次 4D 流采集代替多次 2D 流测量。

材料和方法

使用 kt-GRAPPA 加速 4D 流序列。通过正向(FFV)、反向(BFV)和净流量(NFV)[ml/心跳]评估流量体积,通过轴向(VAX)和绝对速度(VABS)[m/s]评估流量速度,共对 116 名志愿者(58 名女性,43±13 岁)进行了评估。计算主动脉瓣反流分数(RF)。

结果

升主动脉的性别中性平均 FFV、BFV、NFV 和 RF 分别为 93.5±14.8、3.6±2.8、89.9±0.6ml/心跳和 3.9±2.9%。男性的 FFV、BFV、NFV 和 RF 值明显较高,但 VAX 和 VABS 没有性别依赖性。最大平均 VAX 较低(1.01±0.31m/s),而 VABS 较高(1.23±0.35m/s)。我们能够确定所有预期参数的正常范围。

结论

本研究提供了健康志愿者的 4D 流衍生的胸主动脉 2D 流参数的定量正常值。FFV、BFV、NFV 和 VAX 与单次 2D 流采集没有显著差异,因此可以替代耗时的多次 2D 流采集。VABS 不应互换使用。

重点

·4D 流 MRI 可用于替代 2D 流 MRI 测量。·参数绝对速度可通过 4D 流 MRI 评估。·在正向、反向、净主动脉血流和主动脉瓣反流分数方面存在性别依赖性差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验