To utilize 4 D flow MRI to acquire normal values of "conventional 2 D flow MRI parameters" in healthy volunteers in order to replace multiple single 2 D flow measurements with a single 4 D flow acquisition.
A kt-GRAPPA accelerated 4 D flow sequence was used. Flow volumes were assessed by forward (FFV), backward (BFV), and net flow volumes (NFV) [ml/heartbeat] and flow velocities by axial (VAX) and absolute velocity (VABS) [m/s] in 116 volunteers (58 females, 43 ± 13 years). The aortic regurgitant fraction (RF) was calculated.
The sex-neutral mean FFV, BFV, NFV, and RF in the ascending aorta were 93.5 ± 14.8, 3.6 ± 2.8, 89.9 ± 0.6 ml/heartbeat, and 3.9 ± 2.9 %, respectively. Significantly higher values were seen in males regarding FFV, BFV, NFV and RF, but there was no sex dependency regarding VAX and VABS. The mean maximum VAX was lower (1.01 ± 0.31 m/s) than VABS (1.23 ± 0.35 m/s). We were able to determine normal ranges for all intended parameters.
This study provides quantitative 4 D flow-derived thoracic aortic normal values of 2 D flow parameters in healthy volunteers. FFV, BFV, NFV, and VAX did not differ significantly from single 2 D flow acquisitions and could therefore replace time-consuming multiple single 2 D flow acquisitions. VABS should not be used interchangeably.
· 4 D flow MRI can be used to replace 2 D flow MRI measurements.. · The parameter absolute velocities can be assessed by 4 D flow MRI.. · There are sex-dependent differences regarding forward, backward, net aortic blood flow and the aortic valve regurgitant fraction..
利用 4D 流 MRI 获取健康志愿者“传统 2D 流 MRI 参数”的正常值,以便用单次 4D 流采集代替多次 2D 流测量。
使用 kt-GRAPPA 加速 4D 流序列。通过正向(FFV)、反向(BFV)和净流量(NFV)[ml/心跳]评估流量体积,通过轴向(VAX)和绝对速度(VABS)[m/s]评估流量速度,共对 116 名志愿者(58 名女性,43±13 岁)进行了评估。计算主动脉瓣反流分数(RF)。
升主动脉的性别中性平均 FFV、BFV、NFV 和 RF 分别为 93.5±14.8、3.6±2.8、89.9±0.6ml/心跳和 3.9±2.9%。男性的 FFV、BFV、NFV 和 RF 值明显较高,但 VAX 和 VABS 没有性别依赖性。最大平均 VAX 较低(1.01±0.31m/s),而 VABS 较高(1.23±0.35m/s)。我们能够确定所有预期参数的正常范围。
本研究提供了健康志愿者的 4D 流衍生的胸主动脉 2D 流参数的定量正常值。FFV、BFV、NFV 和 VAX 与单次 2D 流采集没有显著差异,因此可以替代耗时的多次 2D 流采集。VABS 不应互换使用。
·4D 流 MRI 可用于替代 2D 流 MRI 测量。·参数绝对速度可通过 4D 流 MRI 评估。·在正向、反向、净主动脉血流和主动脉瓣反流分数方面存在性别依赖性差异。