Suppr超能文献

低IgG水平献血者血浆置换的安全性:一项前瞻性、对照多中心研究的结果

Safety of Plasmapheresis in Donors with Low IgG Levels: Results of a Prospective, Controlled Multicentre Study.

作者信息

Moog Rainer, Laitinen Teija, Taborski Uwe

机构信息

Octapharma Plasma GmbH, Langenfeld, Germany.

出版信息

Transfus Med Hemother. 2022 Apr 14;49(5):271-279. doi: 10.1159/000522528. eCollection 2022 Sep.

Abstract

BACKGROUND AND OBJECTIVES

Although plasmapheresis is generally considered safe, there are still concerns about the long-term effects of plasma donation on immunoglobulin G (IgG) levels. The aim of the present study was to investigate if there is a need to permanently defer donors who donated three times with an IgG level below 6.0 g/L.

STUDY DESIGN AND METHODS

From September 2007 to December 2017, adverse events (AEs) including infections were analysed from data of a prospective, controlled multicentre study of healthy volunteer donors, participating in an individualized plasmapheresis programme stratified by initial IgG level and body weight (individualized arm) or in standard plasmapheresis according to national guidelines (control arm). IgG was monitored at every fifth donation, and donors with IgG levels below the threshold were identified and followed up for possible AEs.

RESULTS

In total, 97,540 donations in 1,462 donors in the control arm and 1,491,223 donations in 14,281 donors in the individualized arm were included. Donation-based incidences of at least severe AEs and any infections were 0.019% and 0.192% in the control arm, and 0.014% and 0.153% in the individualized arm. Three or more IgG-measurements below the threshold occurred in 38.2% of control arm donors and 20.9% of individualized arm donors. There were no increased incidence rates of at least severe AEs or any infections in donors with ≥3 IgG-measurements below the threshold in either donor's arm.

CONCLUSIONS

Our data show no signs of compromised donor safety in donors with ≥3 IgG-measurements below the threshold, indicating that plasmapheresis is feasible and safe in these donors.

摘要

背景与目的

尽管血浆置换通常被认为是安全的,但人们仍担心血浆捐献对免疫球蛋白G(IgG)水平的长期影响。本研究的目的是调查是否有必要永久推迟那些IgG水平低于6.0 g/L且已捐献三次的捐献者。

研究设计与方法

2007年9月至2017年12月,从前瞻性、对照多中心健康志愿者捐献者研究数据中分析包括感染在内的不良事件(AE),这些捐献者参与了根据初始IgG水平和体重分层的个体化血浆置换计划(个体化组)或按照国家指南进行的标准血浆置换(对照组)。每五次捐献时监测IgG,识别出IgG水平低于阈值的捐献者并对其可能的不良事件进行随访。

结果

对照组共纳入1462名捐献者的97540次捐献,个体化组共纳入14281名捐献者的1491223次捐献。对照组基于捐献的至少严重不良事件和任何感染的发生率分别为0.019%和0.192%,个体化组分别为0.014%和0.153%。对照组38.2%的捐献者和个体化组20.9%的捐献者出现三次或更多次IgG测量值低于阈值的情况。在。在任何一组中,IgG测量值低于阈值≥3次的捐献者中,至少严重不良事件或任何感染的发生率均未增加。

结论

我们的数据显示,IgG测量值低于阈值≥3次的捐献者没有出现供体安全性受损的迹象,这表明这些捐献者进行血浆置换是可行且安全的。