Mets J T
S Afr Med J. 1987 Jan 10;71(1):35-9.
Pure-tone audiometry is at present regarded as the best available method in industry for the monitoring of noise-induced occupational hearing loss. The legal obligations and guidelines regarding this procedure are discussed in respect of the situation in the RSA and in other countries, and problems resulting from the time-growth curve for noise-induced hearing loss are emphasised. A survey of audiometric tests performed on 47 healthy men aged 20-41 years exposed to noise levels of 85-92 dB for at least 5 years is reported. The results of this survey reveal the limitations of audiometric monitoring. Some recommendations are made which would take account of these limitations and thus increase the reliability of audiometry in industry.
目前,纯音听力测定法被认为是工业领域监测噪声性职业性听力损失的最佳可用方法。结合南非和其他国家的情况,讨论了有关该程序的法律义务和指导方针,并强调了噪声性听力损失时间增长曲线所带来的问题。报告了一项对47名年龄在20至41岁之间、暴露于85至92分贝噪声水平至少5年的健康男性进行听力测试的调查。这项调查结果揭示了听力测定监测的局限性。提出了一些建议,这些建议将考虑到这些局限性,从而提高工业中听力测定的可靠性。