Suppr超能文献

镜面反射后的X射线束质量:四代储存环光束线中环形镜的实验与模拟结果

X-ray beam quality after a mirror reflection: Experimental and simulated results for a toroidal mirror in a 4 generation storage-ring beamline.

作者信息

Reyes-Herrera Juan, Celestre Rafael, Cammarata Marco, Barrett Raymond, Levantino Matteo, Sanchez Del Rio Manuel

机构信息

European Synchrotron Radiation Facility, Grenoble, 38043, France.

出版信息

Open Res Eur. 2023 Oct 12;3:173. doi: 10.12688/openreseurope.16211.1. eCollection 2023.

Abstract

BACKGROUND

The surface errors found in X-ray mirrors constitute a limiting factor for preserving beam quality. This is particularly important when the X-ray beam has low emittance and a significant coherence fraction, like in newly upgraded synchrotron storage rings.

METHODS

We studied the fringes observed in the image of an undulator-produced X-ray beam reflected by a high-quality toroidal mirror. The measurements and simulations were performed using different conditions: a photon beam either monochromatic or with large bandwidth, reflected by a mirror with variable curvature.

RESULTS

The experimental data are compared with up-to-date simulation including partial coherence.

CONCLUSIONS

The observed fringes in the unfocused beam correlate with low spatial frequency structures in mirror profiles, irrespective of beam coherence. Both classical ray tracing and partially coherent simulations through coherent mode decomposition are confirmed as accurate methods for such simulations.

摘要

背景

X射线镜中发现的表面误差是保持光束质量的一个限制因素。当X射线束具有低发射度和显著的相干分数时,这一点尤为重要,就像在新升级的同步加速器储存环中那样。

方法

我们研究了由高质量环形镜反射的波荡器产生的X射线束图像中观察到的条纹。测量和模拟是在不同条件下进行的:光子束要么是单色的,要么具有大带宽,由具有可变曲率的镜子反射。

结果

将实验数据与包括部分相干性的最新模拟进行了比较。

结论

在未聚焦光束中观察到的条纹与镜轮廓中的低空间频率结构相关,与光束相干性无关。经典光线追踪和通过相干模式分解的部分相干模拟都被确认为进行此类模拟的准确方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dd91/10660299/8fe2f0c5105f/openreseurope-3-17499-g0000.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验