Suppr超能文献

比较LMA ProSeal™与i-gel在头部旋转时的漏气压力:一项随机对照试验。

Comparing leak pressure of LMA ProSeal™ versus i-gel at head rotation: a randomized controlled trial.

作者信息

Chaki Tomohiro, Koizumi Masatsugu, Tachibana Shunsuke, Matsumoto Tomomi, Kumagai Tomoe, Hashimoto Yuki, Yamakage Michiaki

机构信息

Department of Anesthesiology, Sapporo Medical University School of Medicine, Sapporo, Japan.

出版信息

Can J Anaesth. 2024 Jan;71(1):66-76. doi: 10.1007/s12630-023-02648-3. Epub 2023 Nov 28.

Abstract

PURPOSE

The effect of head rotation on supraglottic airway (SGA) oropharyngeal leak pressure (OPLP) has not been well elucidated. The aim of this study was to help clarify which SGA device provides higher OPLP at head-rotated position.

METHODS

Patients who underwent elective surgery under general anesthesia were enrolled and randomly divided into laryngeal mask airway (LMA) ProSeal™ and i-gel groups. The allocated SGA device was inserted under anesthesia. The primary outcome was OPLP, and secondary outcomes were ventilation score, expiratory tidal volume, and maximum pressure under volume-controlled ventilation (VCV) with an inspiratory tidal volume of 10 mL·kg ideal body weight and fibreoptic view of the vocal cords at 0°, 30°, and 60° head rotation.

RESULTS

Data from 78 and 76 patients were analyzed in the LMA ProSeal and i-gel groups, respectively. The mean (standard deviation) OPLP of the LMA ProSeal was significantly higher than that of the i-gel at the 60° head-rotated position (LMA ProSeal, 20.4 [6.5] vs i-gel, 16.9 [7.8] cm HO; difference in means, 3.6; adjusted 95% confidence interval, 0.5 to 6.6; adjusted P = 0.02, adjusted for six comparisons). The maximum pressure under VCV at 60° head rotation was significantly higher in the LMA ProSeal group than in the i-gel group. The expiratory tidal volume of the LMA ProSeal did not significantly change with head rotation and was significantly higher than that of the i-gel at 60° head rotation. Ventilation score, fibreoptic view of the vocal cords, and complications were not significantly different between the ProSeal and i-gel groups.

CONCLUSIONS

The LMA ProSeal provides higher OPLP than the i-gel at a 60° head-rotated position under general anesthesia.

TRIAL REGISTRATION

Japan Registry of Clinical Trials (https://jrct.niph.go.jp) (JRCT1012210043); registered 18 October 2021.

摘要

目的

头部旋转对声门上气道(SGA)口咽漏气压(OPLP)的影响尚未得到充分阐明。本研究的目的是帮助明确哪种SGA装置在头部旋转位置时能提供更高的OPLP。

方法

纳入接受全身麻醉下择期手术的患者,并随机分为喉罩气道(LMA)ProSeal™组和i-gel组。在麻醉下插入分配的SGA装置。主要结局指标为OPLP,次要结局指标为通气评分、呼气潮气量、吸气潮气量为10 mL·kg理想体重时容量控制通气(VCV)下的最大压力以及头部旋转0°、30°和60°时声带的纤维喉镜视野。

结果

分别对LMA ProSeal组和i-gel组的78例和76例患者的数据进行了分析。在头部旋转60°位置时,LMA ProSeal的平均(标准差)OPLP显著高于i-gel(LMA ProSeal,20.4 [6.5] vs i-gel,16.9 [7.8] cm H₂O;均值差异,3.6;校正95%置信区间,0.5至6.6;校正P = 0.02,针对六项比较进行校正)。在头部旋转60°时,LMA ProSeal组VCV下的最大压力显著高于i-gel组。LMA ProSeal的呼气潮气量不会随头部旋转而显著变化,且在头部旋转60°时显著高于i-gel。ProSeal组和i-gel组之间的通气评分、声带纤维喉镜视野及并发症无显著差异。

结论

在全身麻醉下头部旋转60°位置时,LMA ProSeal比i-gel能提供更高的OPLP。

试验注册

日本临床试验注册中心(https://jrct.niph.go.jp)(JRCT1012210043);于2021年10月18日注册。